Lung Size Measurement in Left‐Sided Congenital Diaphragmatic Hernia: Does Position of the Fetus Affect Results?
Prenatal Diagnosis · 2026-08 · 46 (9) · 1480-1485
DOI: 10.1002/pd.70222 ↗At a glance
Journal article in Prenatal Diagnosis, published online on 2026-07-12. Written by Rogelio Cruz-Martínez and 6 co-authors. Institution: Instituto Medicina Fetal México, Guadalajara, Jalisco, Mexico. Major MEDLINE topics: Hernias, Diaphragmatic, Congenital, Ultrasonography, Prenatal, Lung. 19 references. The full text is freely available in PubMed Central.
Abstract (original language)
Objective
To compare the difference in lung size measurement in fetuses with left‐sided congenital diaphragmatic hernia (L‐CDH) by means of the observed/expected lung‐to‐head ratio (O/E‐LHR) in two different fetal positions.
Method
Prospective cohort of L‐CDH fetuses, with O/E‐LHR measurements by one experienced investigator but with the fetus in two positions: with the contralateral lung close and one with the lung away from the ultrasound probe. A Bland‐Altman analysis was performed to assess the agreement between lung measurements in both fetal positions.
Results
49 L‐CDH fetuses underwent paired assessments of lung size at a mean gestational age of 28.8 (17.7–37.7) weeks. Lung size estimation with the lung distant to the probe consistently underestimates the O/E‐LHR values compared to measurements obtained using the lung close to the probe. On average, O/E‐LHR values were 11.3% (95% confidence intervals (CI), 7.5%–15.0%) higher when the lung was close to the probe. When the lung was distant to the probe, a higher proportion of CDH fetuses were classified in a more severe group than when it was evaluated close to the probe ( p < 0.01). A consistently lower survival rate was expected when the lung was evaluated distant to the ultrasound probe.
Conclusions
Lung size estimation in L‐CDH fetuses may be affected by fetal position, which may affect postnatal prognosis, prediction of survival and eligibility for fetal therapy.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Instituto Medicina Fetal México, Guadalajara, Jalisco, Mexico.
- Servicio de Medicina Fetal, Hospital Privado Universitario de Córdoba, Córdoba, Argentina.
- Instituto de Ciencias Biomédicas de Córdoba, Córdoba, Argentina.
- Section of Fetal Therapy and Fetal Surgery Unit, Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Hospital de San José, Fundación Universitaria de Ciencias de la Salud (FUCS), Bogotá, Colomb…
- Maternal-Fetal Medicine Unit, Department of Gynecology and Obstetrics, Faculty of Medicine, Universidad Nacional de Colombia, Bogotá, Colombia.
ORCID profiles: Rogelio Cruz-Martínez, Rosa Villalobos-Gómez, Savino Gil-Pugliese
Cite
APA
Cruz-Martínez, R., Rivera-Carrillo, P., Villalobos-Gómez, R., Peláez-Jiménez, A., Cisneros-Martínez, A., Gil-Pugliese, S., & Molina-Giraldo, S. (2026). Lung Size Measurement in Left‐Sided Congenital Diaphragmatic Hernia: Does Position of the Fetus Affect Results?. Prenatal Diagnosis, 46(9), 1480-1485. https://doi.org/10.1002/pd.70222
Vancouver
Cruz-Martínez R, Rivera-Carrillo P, Villalobos-Gómez R, Peláez-Jiménez A, Cisneros-Martínez A, Gil-Pugliese S, et al. Lung Size Measurement in Left‐Sided Congenital Diaphragmatic Hernia: Does Position of the Fetus Affect Results?. Prenatal Diagnosis. 2026;46(9):1480-1485. doi:10.1002/pd.70222
BibTeX
@article{CruzMartnez2026,
author = {Cruz-Martínez, Rogelio and Rivera-Carrillo, Paola and Villalobos-Gómez, Rosa and Peláez-Jiménez, Andrea and Cisneros-Martínez, Adriana and Gil-Pugliese, Savino and Molina-Giraldo, Saulo},
title = {Lung Size Measurement in Left‐Sided Congenital Diaphragmatic Hernia: Does Position of the Fetus Affect Results?},
journal = {Prenatal Diagnosis},
year = {2026},
volume = {46},
number = {9},
pages = {1480--1485},
doi = {10.1002/pd.70222}
}
EUVIMED