Comparison of Insertion Difficulties and Performance of Thoracoamniotic Shunts for Fetal Hydrothorax
Prenatal Diagnosis · 2026-01 · 46 (1) · 105-113
DOI: 10.1002/pd.70048 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Prenatal Diagnosis, online erschienen am 12.12.2025. Verfasst von Tess T Treurniet und 26 weiteren Autor:innen. Beteiligte Einrichtung: Division of Fetal Medicine, Department of Obstetrics, Leiden University Medical Centre, Leiden, the Netherlands. Hauptthemen laut MEDLINE: Fetal Diseases, Hydrothorax. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
This study compared insertion difficulties, shunt failure, reintervention rates, maternal adverse events, and neonatal outcomes among different shunt types used in fetal hydrothorax.
Method
A retrospective multicenter cohort study (2012–2022) was conducted across 12 international centers. The primary outcome was the occurrence of complications, classified as insertion difficulties and shunt failure (dislocation, occlusion, or unexplained shunt failure). Secondary outcomes included reintervention rates, maternal complications, and neonatal survival.
Results
Among 349 cases, 345 were included in the analysis of the outcome measures. Rodeck shunts had significantly fewer complications (19.5%) compared to Somatex (38.3%, OR 2.53, p = 0.016) and Harrison shunts (50.0%, OR 3.82, p < 0.001). Somatex shunts had the highest rate of incorrect positioning (16%), while dislocation was most frequent with Harrison shunts (31.1%). Reintervention rates were lowest for Rodeck (12.1%) and highest for Harrison (32.2%). Maternal body mass index, fetal hydrops, laterality and year of shunt placement did not significantly influence complication rates. No significant differences in live birth rates or gestational age at delivery were observed.
Conclusions
The Rodeck shunt was associated with fewer insertion difficulties, better shunt performance and lower reintervention rates. There was no difference in perinatal survival among the three shunt types.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Fetal Medicine, Department of Obstetrics, Leiden University Medical Centre, Leiden, the Netherlands.
- Department of Obstetrics & Gynecology, Fetal Medicine Unit & Ontario Fetal Centre, Mount Sinai Hospital, University of Toronto, Toronto, Ontario, Canada.
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, the Netherlands.
- Department of Fertility, Gynecology and Obstetrics, Copenhagen University Hospital Rigshospitalet, Copenhagen, Denmark.
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.
- Fetal Medicine Unit, St George's Hospital, City St George's University of London, London, UK.
ORCID-Profile: Tess T Treurniet, Gillian Blayney, Roland Devlieger, Liesbeth Lewi, Anna L David, Asma Khalil, Ladina Vonzun, Kenneth J Moise, E J T Joanne Verweij, Monique C Haak
Zitieren
APA
Treurniet, T. T., Abbasi, N., Ryan, G., Witlox, R. S. G. M., Slaghekke, F., Nørgaard, L. N., Sundberg, K., Lindgren, P., Ek, S., Thilaganathan, B., Blayney, G., Devlieger, R., Lewi, L., Johnson, A., Pacora Portella, P. N., David, A. L., Vieira, M., Khalil, A., Poljak, B., …, & Haak, M. C. (2026). Comparison of Insertion Difficulties and Performance of Thoracoamniotic Shunts for Fetal Hydrothorax. Prenatal Diagnosis, 46(1), 105-113. https://doi.org/10.1002/pd.70048
Vancouver
Treurniet TT, Abbasi N, Ryan G, Witlox RSGM, Slaghekke F, Nørgaard LN, et al. Comparison of Insertion Difficulties and Performance of Thoracoamniotic Shunts for Fetal Hydrothorax. Prenatal Diagnosis. 2026;46(1):105-113. doi:10.1002/pd.70048
BibTeX
@article{Treurniet2026,
author = {Treurniet, Tess T and Abbasi, Nimrah and Ryan, Greg and Witlox, Ruben S G M and Slaghekke, Femke and Nørgaard, Lone Nikoline and Sundberg, Karin and Lindgren, Peter and Ek, Sverker and Thilaganathan, Basky and Blayney, Gillian and Devlieger, Roland and Lewi, Liesbeth and Johnson, Anthony and Pacora Portella, Percy N and David, Anna L and Vieira, Matias and Khalil, Asma and Poljak, Borna and Vonzun, Ladina and Ochsenbein-Koelble, Nicole and Choolani, Mahesh and Gosavi, Arundhati and Moise, Kenneth J and Hutson, Emily and Verweij, E J T Joanne and Haak, Monique C},
title = {Comparison of Insertion Difficulties and Performance of Thoracoamniotic Shunts for Fetal Hydrothorax},
journal = {Prenatal Diagnosis},
year = {2026},
volume = {46},
number = {1},
pages = {105--113},
doi = {10.1002/pd.70048}
}