National registry of thoracoamniotic shunting using a double‐basket catheter: A post‐marketing surveillance registry of 295 patients with fetal hydrothorax
Prenatal Diagnosis · 2024-07 · 44 (8) · 971-978
DOI: 10.1002/pd.6587 ↗Kurz gefasst
Fachartikel in der Zeitschrift Prenatal Diagnosis, online erschienen am 14.05.2024. Verfasst von Yuichiro Takahashi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fetal-Maternal Medicine and Obstetrics, Gifu Prefectural General Medical Center, Gifu, Japan. Hauptthemen laut MEDLINE: Registries, Hydrothorax. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
Objective
We report on the 1‐year outcomes of fetuses who underwent thoracoamniotic shunting (TAS) with a double‐basket catheter for fetal hydrothorax (FHT) using a national post‐marketing surveillance registry.
Methods
This surveillance study was conducted for cases enrolled between 2011 and 2019. Preoperative, operative, and postoperative findings and outcomes had to be reported through the national surveillance website.
Results
Forty‐three institutes enrolled 295 patients. In 60 patients, associated abnormalities were diagnosed after birth. Among the 235 patients with isolated hydrothorax, the survival rate at 1 year of age was 70.5%. Among these patients, 89% did not require oxygen or other respiratory support. The 1‐year survival rate in complicated cases was 27%. Trisomy 21 was the most common associated problem (40%). Catheter associated problems, including dislocation (25%), obstruction (24%), and preterm rupture of the membranes (6%) were observed, but there were no severe maternal complications. TAS before 29.5 weeks of gestation (odds ratio [OR] 0.16) and skin edema and ascites (OR 0.06) were risk factors for death at one year, whereas appropriate shunt location for >28 days (OR 4.2) was a protective factor.
Conclusion
We report a favorable survival rate in fetuses with isolated FHT treated with this double‐basket catheter.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Fetal-Maternal Medicine and Obstetrics, Gifu Prefectural General Medical Center, Gifu, Japan.
- Department of Fetal-Maternal Medicine, Nagara Medical Center, Gifu, Japan.
- Department of Maternal Fetal Medicine, Osaka Women's and Children's Hospital, Osaka, Japan.
- Department of Obstetrics and Gynecology, Kanagawa Children's Medical Center, Yokohama, Japan.
- Department of Obstetrics and Gynecology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- Center for Maternal, Fetal and Neonatal Medicine, Saitama Medical Center, Saitama Medical University, Saitama, Japan.
ORCID-Profile: Yuichiro Takahashi, Keisuke Ishii, Haruhiko Sago
Zitieren
APA
Takahashi, Y., Ishii, K., Ishikawa, H., Imai, K., Baba, K., & Sago, H. (2024). National registry of thoracoamniotic shunting using a double‐basket catheter: A post‐marketing surveillance registry of 295 patients with fetal hydrothorax. Prenatal Diagnosis, 44(8), 971-978. https://doi.org/10.1002/pd.6587
Vancouver
Takahashi Y, Ishii K, Ishikawa H, Imai K, Baba K, Sago H. National registry of thoracoamniotic shunting using a double‐basket catheter: A post‐marketing surveillance registry of 295 patients with fetal hydrothorax. Prenatal Diagnosis. 2024;44(8):971-978. doi:10.1002/pd.6587
BibTeX
@article{Takahashi2024,
author = {Takahashi, Yuichiro and Ishii, Keisuke and Ishikawa, Hiroshi and Imai, Kenji and Baba, Kazunori and Sago, Haruhiko},
title = {National registry of thoracoamniotic shunting using a double‐basket catheter: A post‐marketing surveillance registry of 295 patients with fetal hydrothorax},
journal = {Prenatal Diagnosis},
year = {2024},
volume = {44},
number = {8},
pages = {971--978},
doi = {10.1002/pd.6587}
}
EUVIMED