EUVIMEDSkopri EUVIMED
Crossref

High Intensity Focused Ultrasound‐Induced Ablation of the Intra‐Abdominal Umbilical Vessels in a Rabbit Fetus: A Model Treatment of Twin‐Reversed Arterial Perfusion Sequence

Ava Danialy iD, Nikan Fakhari, Karolina Piorkowska iD, Tao Wang iD, Jerome Baranger, Sydney Nowak, Olivier Villemain, James M Drake, Tim Van Mieghem, Adam C Waspe

Prenatal Diagnosis · 2025

DOI: 10.1002/pd.70010 ↗

At a glance

Journal article in Prenatal Diagnosis, 2025. Written by Ava Danialy and 9 co-authors. Institution: The Hospital for Sick Children, Toronto, Ontario, Canada. Major MEDLINE topics: High-Intensity Focused Ultrasound Ablation, Umbilical Arteries, Fetofetal Transfusion. 41 references. Funded by: CIHR, Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Objective

To assess the efficacy of high intensity focused ultrasound (HIFU) to target and ablate the fetal intra‐umbilical vessels and terminate fetal perfusion in a pregnant rabbit model.

Methods

Pregnant New Zealand white rabbits (gestational age: E25‐27, n = 6 rabbits, n = 18 treated fetuses, n = 6 controls) underwent high‐resolution MRI for fetal localization, orientation assessment, beam guidance, and treatment monitoring. Ultrafast ultrasound with power Doppler quantified cardiac output and placental perfusion pre‐ and post‐treatment. HIFU (100–120Wac, 16–20s) induced thermal ablation; MR‐thermometry monitored intraoperative temperature; histology confirmed ablation. Ultrafast ultrasound imaging and gross examination confirmed termination.

Results

Target fetal livers ( n = 18) reached a maximum temperature of . Ultrafast ultrasound imaging confirmed the termination of target fetuses, verifying the treatment success in 11 fetuses. Successfully treated fetuses showed a 95% ± 7.4% decrease in cardiac output compared with 11% ± 4.6% decrease in controls, p = 0.022. Placental perfusion dropped 83% ± 10.0% in successfully treated fetuses compared with 16% ± 5.5% in control fetuses, p = 0.002. Overall, 83% (15/18) of targeted fetuses were terminated, with adjacent controls surviving. Thermal necrosis was present in all targeted livers.

Conclusions

MR‐guided HIFU can effectively ablate fetal rabbit umbilical vessels to cause selective termination, modeling a non‐invasive treatment for twin reversed arterial perfusion sequence.

Subjects

MeSH terms (MEDLINE)

High-Intensity Focused Ultrasound AblationUmbilical ArteriesFetofetal TransfusionAnimalsRabbitsFemalePregnancyFetusUltrasonography, PrenatalMagnetic Resonance Imaging

Author keywords

cardiac outputenhancementliver necrosismagnetic resonance imagingplacental perfusionthermal ablationthermally coagulative necrosistreatment planningultrafast ultrasound imagingumbilicus

Authors and institutions

  • The Hospital for Sick Children, Toronto, Ontario, Canada.
  • University of Toronto, Toronto, Ontario, Canada.
  • Division of Cardiology, Department of Pediatrics, The Hospital for Sick Children, Toronto, Ontario, Canada.
  • Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada.
  • Department of Pathology and Molecular Medicine, Kingston Health Sciences Centre, Queen's University, Kingston, Ontario, Canada.
  • Physics for Medicine Paris, Inserm, ESPCI PSL Paris, CNRS, Paris, France.

ORCID profiles: Ava Danialy, Karolina Piorkowska, Tao Wang

Funding

  • CIHR
  • Natural Sciences and Engineering Research Council of Canada
  • Canada Foundation for Innovation

Cite

APA

Danialy, A., Fakhari, N., Piorkowska, K., Wang, T., Baranger, J., Nowak, S., Villemain, O., Drake, J. M., Van Mieghem, T., & Waspe, A. C. (2025). High Intensity Focused Ultrasound‐Induced Ablation of the Intra‐Abdominal Umbilical Vessels in a Rabbit Fetus: A Model Treatment of Twin‐Reversed Arterial Perfusion Sequence. Prenatal Diagnosis. https://doi.org/10.1002/pd.70010

Vancouver

Danialy A, Fakhari N, Piorkowska K, Wang T, Baranger J, Nowak S, et al. High Intensity Focused Ultrasound‐Induced Ablation of the Intra‐Abdominal Umbilical Vessels in a Rabbit Fetus: A Model Treatment of Twin‐Reversed Arterial Perfusion Sequence. Prenatal Diagnosis. 2025. doi:10.1002/pd.70010

BibTeX
@article{Danialy2025,
  author = {Danialy, Ava and Fakhari, Nikan and Piorkowska, Karolina and Wang, Tao and Baranger, Jerome and Nowak, Sydney and Villemain, Olivier and Drake, James M and Van Mieghem, Tim and Waspe, Adam C},
  title = {High Intensity Focused Ultrasound‐Induced Ablation of the Intra‐Abdominal Umbilical Vessels in a Rabbit Fetus: A Model Treatment of Twin‐Reversed Arterial Perfusion Sequence},
  journal = {Prenatal Diagnosis},
  year = {2025},
  doi = {10.1002/pd.70010}
}
Start for free →