EUVIMEDObjevte EUVIMED
Systematische ÜbersichtMetaanalyseOpen access · CC BY-NC-ND 4.0

Fetal Speckle Tracking Echocardiography Measured Global Longitudinal Strain and Strain Rate in Congenital Heart Disease: A Systematic Review and Meta‐Analysis

Sarah van den Wildenberg iD, Ingrid M van Beynum, Malou E C Havermans, Eric Boersma, Greggory R DeVore iD, John M Simpson, Eric A P Steegers, Attie T J I Go, Jérôme M J Cornette

Prenatal Diagnosis · 2024-11 · 44 (12) · 1479-1497

DOI: 10.1002/pd.6672 ↗

At a glance

Systematische Übersicht in Prenatal Diagnosis, published online on 2024-10-04. Written by Sarah van den Wildenberg and 8 co-authors. Institution: Department of Obstetrics and Gynecology, Division of Fetal Medicine, Erasmus Medical Center, Rotterdam, The Netherlands. Major MEDLINE topics: Heart Defects, Congenital, Ultrasonography, Prenatal, Echocardiography, Fetal Heart. Cited 13 times so far (Crossref); 69 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Fetal two‐dimensional speckle tracking echocardiography (2D‐STE) is a novel technique that provides information on fetal heart function by measuring global longitudinal strain (GLS) and global longitudinal strain rate (GLSR). These features assess the longitudinal deformity of the fetal cardiac wall. 2D‐STE is shown to be of prognostic value in children and adults with congenital heart disease (CHD). Therefore, its importance in fetal life should also be considered. This systematic review and meta‐analysis provides an overview of the literature on 2D‐STE (GLS/GLSR) in fetuses with CHD, focusing on the left and right ventricles (LV/RV). Findings indicated that LV‐GLS was significantly lower in fetuses with coarctation of the aorta (CoA) and Tetralogy of Fallot (ToF) compared to controls. Conversely, fetuses with a single left ventricle exhibited higher LV‐GLS. RV‐GLS was significantly lower in fetuses with hypoplastic left heart syndrome (HLHS) and ToF compared to controls. LV‐GLSR was significantly lower in fetuses with CoA. Overall, considerable heterogeneity was observed, possibly due to differences in study design. More prospective longitudinal studies on 2D‐STE in fetuses with CHD, considering heterogeneity parameters, could offer better insights into this promising technique.

Subjects

MeSH terms (MEDLINE)

Heart Defects, CongenitalUltrasonography, PrenatalEchocardiographyFetal HeartHumansPregnancyFemaleGlobal Longitudinal Strain

Author keywords

fetal echocardiographyfetal imagingfetal ultrasoundprenatalultrasonography

Authors and institutions

  • Department of Obstetrics and Gynecology, Division of Fetal Medicine, Erasmus Medical Center, Rotterdam, The Netherlands.
  • Department of Pediatrics, Division of Cardiology, Erasmus Medical Center Sophia's Children Hospital, Rotterdam, The Netherlands.
  • Department of Cardiology, Clinical Epidemiology and Statistics Unit, Thorax Center, Cardiovascular Institute, Erasmus Medical Center, Rotterdam, The Netherlands.
  • Fetal Diagnostics Centers, Pasadena, California, USA.
  • Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, David Geffen School of Medicine at UCLA, Los Angeles, California, USA.
  • Department of Obstetrics and Gynecology, Wayne State University, Detroit, Michigan, USA.

ORCID profiles: Sarah van den Wildenberg, Greggory R DeVore

Cite

APA

van den Wildenberg, S., van Beynum, I. M., Havermans, M. E. C., Boersma, E., DeVore, G. R., Simpson, J. M., Steegers, E. A. P., Go, A. T. J. I., & Cornette, J. M. J. (2024). Fetal Speckle Tracking Echocardiography Measured Global Longitudinal Strain and Strain Rate in Congenital Heart Disease: A Systematic Review and Meta‐Analysis. Prenatal Diagnosis, 44(12), 1479-1497. https://doi.org/10.1002/pd.6672

Vancouver

van den Wildenberg S, van Beynum IM, Havermans MEC, Boersma E, DeVore GR, Simpson JM, et al. Fetal Speckle Tracking Echocardiography Measured Global Longitudinal Strain and Strain Rate in Congenital Heart Disease: A Systematic Review and Meta‐Analysis. Prenatal Diagnosis. 2024;44(12):1479-1497. doi:10.1002/pd.6672

BibTeX
@article{vandenWildenberg2024,
  author = {van den Wildenberg, Sarah and van Beynum, Ingrid M and Havermans, Malou E C and Boersma, Eric and DeVore, Greggory R and Simpson, John M and Steegers, Eric A P and Go, Attie T J I and Cornette, Jérôme M J},
  title = {Fetal Speckle Tracking Echocardiography Measured Global Longitudinal Strain and Strain Rate in Congenital Heart Disease: A Systematic Review and Meta‐Analysis},
  journal = {Prenatal Diagnosis},
  year = {2024},
  volume = {44},
  number = {12},
  pages = {1479--1497},
  doi = {10.1002/pd.6672}
}
Start for free →