EUVIMEDAtrasti EUVIMED
Vergleichsstudie

Postmortem imaging of fetuses at early gestations: A comparison of microfocus computed tomography with postmortem magnetic resonance at 9.4 T and postmortem ultrasound

Patricia Ibarra Vilar, Jacques C Jani iD, Mieke M Cannie iD, Susan C Shelmerdine iD, Sophie Lecomte iD, Marleen Verhoye iD, Ciaran J Hutchinson iD, Owen J Arthurs iD, Andrew Carlin iD, Xin Kang iD

Prenatal Diagnosis · 2024

DOI: 10.1002/pd.6532 ↗

At a glance

Vergleichsstudie in Prenatal Diagnosis, 2024. Written by Patricia Ibarra Vilar and 9 co-authors. Institution: Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium. Major MEDLINE topics: Fetus, Gestational Age, Magnetic Resonance Imaging, Postmortem Imaging. Cited 10 times so far (Crossref); 17 references. Funded by: Medical Research Council, National Institute for Health and Care Research.

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Objective

To compare the diagnostic performance of postmortem ultrasound (PMUS), 9.4 T magnetic resonance imaging (MRI) and microfocus computed tomography (micro‐CT) for the examination of early gestation fetuses.

Method

Eight unselected fetuses (10–15 weeks gestational age) underwent at least 2 of the 3 listed imaging examinations. Six fetuses underwent 9.4 T MRI, four underwent micro‐CT and six underwent PMUS. All operators were blinded to clinical history. All imaging was reported according to a prespecified template assessing 36 anatomical structures, later grouped into five regions: brain, thorax, heart, abdomen and genito‐urinary.

Results

More anatomical structures were seen on 9.4 T MRI and micro‐CT than with PMUS, with a combined frequency of identified structures of 91.9% and 69.7% versus 54.5% and 59.6 ( p < 0.001; p < 0.05) respectively according to comparison groups. In comparison with 9.4 T MRI, more structures were seen on micro‐CT (90.2% vs. 83.3%, p < 0.05). Anatomical structures were described as abnormal on PMUS in 2.7%, 9.4 T MRI in 6.1% and micro‐CT 7.7% of all structures observed. However, the accuracy test could not be calculated because conventional autopsy was performed on 6 fetuses of that only one structure was abnormal.

Conclusion

Micro‐CT appears to offer the greatest potential as an imaging adjunct or non‐invasive alternative for conventional autopsies in early gestation fetuses.

Subjects

MeSH terms (MEDLINE)

FetusGestational AgeMagnetic Resonance ImagingPostmortem ImagingAdultFemaleHumansPregnancyUltrasonography, PrenatalX-Ray Microtomography

Authors and institutions

  • Department of Obstetrics and Gynecology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium.
  • Department of Radiology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium.
  • Great Ormond Street Hospital for Children NHS Foundation Trust, London, UK.
  • Department of Pathology, University Hospital Brugmann, Université Libre de Bruxelles, Brussels, Belgium.
  • Bio-Imaging Lab, University of Antwerp, Antwerp, Belgium.
  • NIHR Great Ormond Street Hospital Biomedical Research Centre, London, UK.

ORCID profiles: Jacques C Jani, Mieke M Cannie, Susan C Shelmerdine, Sophie Lecomte, Marleen Verhoye, Ciaran J Hutchinson, Owen J Arthurs, Andrew Carlin, Xin Kang

Funding

  • Medical Research Council
  • National Institute for Health and Care Research

Cite

APA

Ibarra Vilar, P., Jani, J. C., Cannie, M. M., Shelmerdine, S. C., Lecomte, S., Verhoye, M., Hutchinson, C. J., Arthurs, O. J., Carlin, A., & Kang, X. (2024). Postmortem imaging of fetuses at early gestations: A comparison of microfocus computed tomography with postmortem magnetic resonance at 9.4 T and postmortem ultrasound. Prenatal Diagnosis. https://doi.org/10.1002/pd.6532

Vancouver

Ibarra Vilar P, Jani JC, Cannie MM, Shelmerdine SC, Lecomte S, Verhoye M, et al. Postmortem imaging of fetuses at early gestations: A comparison of microfocus computed tomography with postmortem magnetic resonance at 9.4 T and postmortem ultrasound. Prenatal Diagnosis. 2024. doi:10.1002/pd.6532

BibTeX
@article{IbarraVilar2024,
  author = {Ibarra Vilar, Patricia and Jani, Jacques C and Cannie, Mieke M and Shelmerdine, Susan C and Lecomte, Sophie and Verhoye, Marleen and Hutchinson, Ciaran J and Arthurs, Owen J and Carlin, Andrew and Kang, Xin},
  title = {Postmortem imaging of fetuses at early gestations: A comparison of microfocus computed tomography with postmortem magnetic resonance at 9.4 T and postmortem ultrasound},
  journal = {Prenatal Diagnosis},
  year = {2024},
  doi = {10.1002/pd.6532}
}
Start for free →