EUVIMEDEUVIMED entdecken
Crossref

Engineering Electroactive 3D Scaffolds: Evaluation of Electrical Properties, Mechanical Performance, and Cytocompatibility for Potential Use in Meniscus Tissue Engineering

Sathish Paramasivam Bhama, Punniyadharshini Soundharraj, Unnamalai Senthilnathan, Snehaa Subash, Selvakumar Rajendran

Polymers for Advanced Technologies · 2026-11 · 37 (11)

DOI: 10.1002/pat.70788 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Polymers for Advanced Technologies, online erschienen am 10.11.2026. Verfasst von Sathish Paramasivam Bhama und 4 weiteren Autor:innen. Die Arbeit nennt 74 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electroconductive bioink (ECB) offers a promising strategy to overcome the drawbacks of growth factors incorporated into conventional bioinks, thereby improving the biofunctionality of engineered 3D scaffolds for meniscal regeneration. In this study, an ECB was prepared using a tricomposite bioink consisting of gelatin, carboxymethyl cellulose (CMC), alginate, and CMC‐reduced gold nanospheres (GNS). Electroactive 3D scaffolds were developed using an indirect 3D printing technique and evaluated for their morphological, electrical, mechanical, and biological properties. Morphological characterization showed that the 3D electroactive scaffolds had an interconnected porous network with a pore size of 261 ± 95.55 μm, which is beneficial for meniscal regeneration. GNS reinforcement in the tripolymer chain significantly improved the electrical conductivity of the electroactive 3D scaffolds by 260%. Furthermore, the affinity between the GNS and tripolymer chains increased the mechanical stability and structural integrity of the electroactive 3D scaffolds, thereby increasing compressive strength and reducing in vitro degradation. The electroactive components in the electroactive 3D scaffolds increased cell proliferation (103%) and spreading in L929 cell viability assays. The findings highlight the structural integrity, superior electrical conductivity, and cytocompatibility of the proposed electroactive 3D scaffolds, underscoring their potential for patient‐specific meniscal tissue engineering applications.

Zitieren

APA

Bhama, S. P., Soundharraj, P., Senthilnathan, U., Subash, S., & Rajendran, S. (2026). Engineering Electroactive 3D Scaffolds: Evaluation of Electrical Properties, Mechanical Performance, and Cytocompatibility for Potential Use in Meniscus Tissue Engineering. Polymers for Advanced Technologies, 37(11). https://doi.org/10.1002/pat.70788

Vancouver

Bhama SP, Soundharraj P, Senthilnathan U, Subash S, Rajendran S. Engineering Electroactive 3D Scaffolds: Evaluation of Electrical Properties, Mechanical Performance, and Cytocompatibility for Potential Use in Meniscus Tissue Engineering. Polymers for Advanced Technologies. 2026;37(11). doi:10.1002/pat.70788

BibTeX
@article{Bhama2026,
  author = {Bhama, Sathish Paramasivam and Soundharraj, Punniyadharshini and Senthilnathan, Unnamalai and Subash, Snehaa and Rajendran, Selvakumar},
  title = {Engineering Electroactive 3D Scaffolds: Evaluation of Electrical Properties, Mechanical Performance, and Cytocompatibility for Potential Use in Meniscus Tissue Engineering},
  journal = {Polymers for Advanced Technologies},
  year = {2026},
  volume = {37},
  number = {11},
  doi = {10.1002/pat.70788}
}
Kostenlos starten →