Volume Guarantee Versus Manual Tidal Volume Monitoring During High‐Frequency Oscillatory Ventilation in Neonates: A Pilot Randomized Controlled Trial
Pediatric Anesthesia · 12.11.2026
DOI: 10.1002/pan.70349 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Pediatric Anesthesia, online erschienen am 12.11.2026. Verfasst von Siddhavatam Rahul Karthik und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
Objective
The present study compared the effects of high‐frequency oscillatory ventilation (HFOV) with automated volume guarantee (HFOV‐VG) versus careful manual high‐frequency tidal volume (VThf) monitoring (HFOV‐VM) on the incidences of hypo/hypercarbia in neonates.
Methods
In this open‐labeled, parallel‐group randomized controlled trial, 60 neonates failing conventional mechanical ventilation were allocated to receive HFOV‐VG ( n = 30) versus HFOV‐VM ( n = 30) as a rescue mode. The primary outcome was the incidence of hypo/hypercarbia at 1 h. Secondary outcomes were incidences of hypo/hypercarbia at 6/12/24/48 h and beyond, time‐specific trends for partial pressure of carbon dioxide (pCO 2 ), delivered VThf and mean airway pressure (MAP), cerebral blood flow (CBF) in the anterior cerebral artery (ACA) and regional cerebral oxygenation (CrSO 2 ), duration of respiratory support, and incidences of in‐hospital adverse events. Stata 18 was used for an intention‐to‐treat analysis.
Results
The incidence of hypo‐ or hypercarbia at 1 h of intervention was 15/30 (50%) in the HFOV‐VG and 13/30 (43%) in the HFOV‐VM groups ( p = 0.61). No differences were observed in the incidences of hypo‐ or hypercarbia anytime during HFOV. Time‐specific pCO 2 , VThf, and MAP were similar. On regression analysis, the only significant predictor for pCO 2 at 1 h was the baseline pCO 2 level in both the groups. No difference was observed in ACA‐CBF, CrSO 2 , duration of respiratory support, and in‐hospital adverse events including mortality.
Conclusion
There was no difference in the incidence of hypo/hypercarbia with HFOV‐VG versus HFOV‐VM at 1 h and throughout the duration of ventilation with a similar rate of complications when used as a rescue therapy. Trial Registration Clinical trial registry of India, Registration no: CTRI/2024/09/073455, Registered prospectively on 05/09/2024, https://ctri.icmr.org.in/
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neonatology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
- Department of Pediatrics, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India.
ORCID-Profile: Siddhavatam Rahul Karthik, Mayank Priyadarshi, Poonam Singh, Suman Chaurasia, Sriparna Basu
Zitieren
APA
Karthik, S. R., Mazhari, M. Y. A., Priyadarshi, M., Singh, P., Chaurasia, S., Bhat, N. K., & Basu, S. (2026). Volume Guarantee Versus Manual Tidal Volume Monitoring During High‐Frequency Oscillatory Ventilation in Neonates: A Pilot Randomized Controlled Trial. Pediatric Anesthesia. https://doi.org/10.1002/pan.70349
Vancouver
Karthik SR, Mazhari MYA, Priyadarshi M, Singh P, Chaurasia S, Bhat NK, et al. Volume Guarantee Versus Manual Tidal Volume Monitoring During High‐Frequency Oscillatory Ventilation in Neonates: A Pilot Randomized Controlled Trial. Pediatric Anesthesia. 2026. doi:10.1002/pan.70349
BibTeX
@article{Karthik2026,
author = {Karthik, Siddhavatam Rahul and Mazhari, Mohammad Yusuf Ali and Priyadarshi, Mayank and Singh, Poonam and Chaurasia, Suman and Bhat, Nowneet Kumar and Basu, Sriparna},
title = {Volume Guarantee Versus Manual Tidal Volume Monitoring During High‐Frequency Oscillatory Ventilation in Neonates: A Pilot Randomized Controlled Trial},
journal = {Pediatric Anesthesia},
year = {2026},
doi = {10.1002/pan.70349}
}
EUVIMED