EUVIMEDTutustu EUVIMEDiin
Crossref

Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception

William Pennington-FitzGerald iD, Nicholas A Waring iD, Mickie Hamiter, Megan Kuhlmey, Ana H Kim iD

Otolaryngology–Head and Neck Surgery · 2025-03 · 172 (3) · 960-966

DOI: 10.1002/ohn.995 ↗

At a glance

Journal article in Otolaryngology–Head and Neck Surgery, published online on 2024-10-06. Written by William Pennington-FitzGerald and 4 co-authors. Institution: Vagelos College of Physicians and Surgeons, Columbia University, New York, New York, USA. Major MEDLINE topics: Speech Perception, Cochlear Implants, Prosthesis Design, Cochlear Implantation. Cited 7 times so far (Crossref); 19 references.

TiivistelmäSubjectsBibliografiset tiedotCiteRelated studies

Abstract (original language)

Objective

Electrode array design may impact hearing outcomes in patients who receive cochlear implants. The goal of this work was to assess differences in post operative speech perception among patients who received cochlear implants of differing designs and lengths. Study Design Retrospective chart review.

Setting

Tertiary Care Hospital.

Methods

Patients (n = 129) received 1 of 9 electrode arrays, which were categorized by design: Lateral wall electrodes (n = 36) included CI522, CI622 (Cochlear Americas), Flex24, and Flex28 (Med El). Midscala electrodes (n = 16) included HiRes Ultra 3D (Advanced Bionics). Perimodiolar electrodes (n = 77) included CI512, CI532, CI612, and CI632 (Cochlear Americas). Speech perception was evaluated using consonant‐nucleus‐consonant (CNC) tests and at 3, 6, 12, and 24 months postimplantation.

Results

Perimodiolar electrodes showed significantly higher CNC scores compared to lateral wall electrodes at 6 and 24 months. Perimodiolar electrodes also outperformed midscala electrodes at 12 months. An inverse relationship was observed between electrode length and CNC scores noted at 6, 12, and 24 months.

Conclusion

Perimodiolar electrode arrays, which tend to be shorter, demonstrated better speech perception outcomes compared to the longer lateral wall and midscala arrays at some timepoints. These findings suggest a potential advantages of perimodiolar electrodes for optimizing hearing outcomes.

Subjects

MeSH terms (MEDLINE)

Speech PerceptionCochlear ImplantsProsthesis DesignCochlear ImplantationElectrodes, ImplantedHumansRetrospective StudiesMaleFemaleMiddle AgedAdultChildChild, PreschoolAgedAdolescentTreatment OutcomePostoperative Period

Author keywords

cochlear implantationelectrode designlateral wallmidscalaperimodiolarspeech perception

Authors and institutions

  • Vagelos College of Physicians and Surgeons, Columbia University, New York, New York, USA.
  • Department of Otolaryngology-Head & Neck Surgery, Columbia University Irving Medical Center, New York, New York, USA.

ORCID profiles: William Pennington-FitzGerald, Nicholas A Waring, Ana H Kim

Cite

APA

Pennington-FitzGerald, W., Waring, N. A., Hamiter, M., Kuhlmey, M., & Kim, A. H. (2025). Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception. Otolaryngology–Head and Neck Surgery, 172(3), 960-966. https://doi.org/10.1002/ohn.995

Vancouver

Pennington-FitzGerald W, Waring NA, Hamiter M, Kuhlmey M, Kim AH. Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception. Otolaryngology–Head and Neck Surgery. 2025;172(3):960-966. doi:10.1002/ohn.995

BibTeX
@article{PenningtonFitzGerald2025,
  author = {Pennington-FitzGerald, William and Waring, Nicholas A and Hamiter, Mickie and Kuhlmey, Megan and Kim, Ana H},
  title = {Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception},
  journal = {Otolaryngology–Head and Neck Surgery},
  year = {2025},
  volume = {172},
  number = {3},
  pages = {960--966},
  doi = {10.1002/ohn.995}
}
Start for free →