Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception
Otolaryngology–Head and Neck Surgery · 2025-03 · 172 (3) · 960-966
DOI: 10.1002/ohn.995 ↗Kurz gefasst
Fachartikel in der Zeitschrift Otolaryngology–Head and Neck Surgery, online erschienen am 06.10.2024. Verfasst von William Pennington-FitzGerald und 4 weiteren Autor:innen. Beteiligte Einrichtung: Vagelos College of Physicians and Surgeons, Columbia University, New York, New York, USA. Hauptthemen laut MEDLINE: Speech Perception, Cochlear Implants, Prosthesis Design, Cochlear Implantation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
Objective
Electrode array design may impact hearing outcomes in patients who receive cochlear implants. The goal of this work was to assess differences in post operative speech perception among patients who received cochlear implants of differing designs and lengths. Study Design Retrospective chart review.
Setting
Tertiary Care Hospital.
Methods
Patients (n = 129) received 1 of 9 electrode arrays, which were categorized by design: Lateral wall electrodes (n = 36) included CI522, CI622 (Cochlear Americas), Flex24, and Flex28 (Med El). Midscala electrodes (n = 16) included HiRes Ultra 3D (Advanced Bionics). Perimodiolar electrodes (n = 77) included CI512, CI532, CI612, and CI632 (Cochlear Americas). Speech perception was evaluated using consonant‐nucleus‐consonant (CNC) tests and at 3, 6, 12, and 24 months postimplantation.
Results
Perimodiolar electrodes showed significantly higher CNC scores compared to lateral wall electrodes at 6 and 24 months. Perimodiolar electrodes also outperformed midscala electrodes at 12 months. An inverse relationship was observed between electrode length and CNC scores noted at 6, 12, and 24 months.
Conclusion
Perimodiolar electrode arrays, which tend to be shorter, demonstrated better speech perception outcomes compared to the longer lateral wall and midscala arrays at some timepoints. These findings suggest a potential advantages of perimodiolar electrodes for optimizing hearing outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Vagelos College of Physicians and Surgeons, Columbia University, New York, New York, USA.
- Department of Otolaryngology-Head & Neck Surgery, Columbia University Irving Medical Center, New York, New York, USA.
ORCID-Profile: William Pennington-FitzGerald, Nicholas A Waring, Ana H Kim
Zitieren
APA
Pennington-FitzGerald, W., Waring, N. A., Hamiter, M., Kuhlmey, M., & Kim, A. H. (2025). Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception. Otolaryngology–Head and Neck Surgery, 172(3), 960-966. https://doi.org/10.1002/ohn.995
Vancouver
Pennington-FitzGerald W, Waring NA, Hamiter M, Kuhlmey M, Kim AH. Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception. Otolaryngology–Head and Neck Surgery. 2025;172(3):960-966. doi:10.1002/ohn.995
BibTeX
@article{PenningtonFitzGerald2025,
author = {Pennington-FitzGerald, William and Waring, Nicholas A and Hamiter, Mickie and Kuhlmey, Megan and Kim, Ana H},
title = {Impact of Cochlear Implant Electrode Array Design on Post‐Op Speech Perception},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2025},
volume = {172},
number = {3},
pages = {960--966},
doi = {10.1002/ohn.995}
}
EUVIMED