EUVIMEDΑνακαλύψτε το EUVIMED
Open access

The Repeatability of Pharyngeal Opening Pressure Under Drug‐Induced Sleep Endoscopy

Tyler G Chan iD, Jack Plageman, Jason L Yu iD

Otolaryngology–Head and Neck Surgery · 2024

DOI: 10.1002/ohn.730 ↗

At a glance

Journal article in Otolaryngology–Head and Neck Surgery, 2024. Written by Tyler G Chan and 2 co-authors. Institution: Emory University School of Medicine, Atlanta, Georgia, USA. Major MEDLINE topics: Continuous Positive Airway Pressure, Pharynx, Sleep Apnea, Obstructive, Endoscopy. Cited 4 times so far (Crossref); 60 references. The full text is freely available in PubMed Central. Funded by: NCATS NIH HHS, NIA NIH HHS.

ΠερίληψηSubjectsΒιβλιογραφικά στοιχείαCiteRelated studies

Abstract (original language)

Objective

Pharyngeal opening pressure (PhOP) is a measure of upper airway collapsibility that can be obtained during drug‐induced sleep endoscopy (DISE) using a continuous positive airway pressure (CPAP) titration. However, the stability of PhOP over the course of sedation during DISE remains unclear. This study aims to compare repeat measures of PhOP over the course of DISE. Study Design Single arm prospective study.

Setting

Single tertiary care institution.

Methods

Patients had 2 CPAP titrations while undergoing DISE. Collected data included patient demographics, PhOP, patient sedation index (PSI), and duration of and between CPAP titrations. t Tests, test‐retest coefficient analysis, and repeated measures correlation were performed.

Results

Twenty‐five patients completed the study between 2022 and 2023 with 22 patients having sedation depth (PSI) recording. Most were male (76%), obese (average body mass index: 30.24 kg/m 2 ), with severe obstructive sleep apnea (average apnea‐hypopnea index: 39.8 events/hr). Test‐retest analysis showed good‐excellent correlation between PhOP values (intraclass correlation coefficient = 0.892, P < .0001, n = 25). Average time between CPAP titrations was 15 minutes to 6 seconds. Over that time, PhOP increased by an average of 0.72 cmH 2 O ( P = .06, n = 25) and PSI decreased by 9.5 units ( P = .01, n = 22). Repeated measures correlation showed a weak negative correlation between PhOP and PSI ( r = −.45, P = .03, n = 22).

Conclusion

The results showed repeatability of PhOP values over the course of DISE. When adjusted for sedation depth (PSI), deeper sedation was weakly associated with greater PHOP. However, the magnitude of this change was small and we conclude that PhOP remains relatively stable over the course of DISE (Effects of Lung Volume on Upper Airway Patency During DISE [DISE‐Pulm], NCT05350332, clinicaltrials.gov ).

Subjects

MeSH terms (MEDLINE)

Continuous Positive Airway PressurePharynxSleep Apnea, ObstructiveEndoscopyHumansMaleFemaleProspective StudiesMiddle AgedReproducibility of ResultsPressureAdultAgedPolysomnographyHypnotics and Sedatives

Author keywords

drug‐induced sleep endoscopyobstructive sleep apneapharyngeal opening pressurerepeatable measuresupper airway collapsibility

Substances

Hypnotics and Sedatives

Authors and institutions

  • Emory University School of Medicine, Atlanta, Georgia, USA.
  • Department of Otolaryngology-Head and Neck Surgery, Emory University, Atlanta, Georgia, USA.

ORCID profiles: Tyler G Chan, Jason L Yu

Funding

  • NCATS NIH HHS
  • NIA NIH HHS

Cite

APA

Chan, T. G., Plageman, J., & Yu, J. L. (2024). The Repeatability of Pharyngeal Opening Pressure Under Drug‐Induced Sleep Endoscopy. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.730

Vancouver

Chan TG, Plageman J, Yu JL. The Repeatability of Pharyngeal Opening Pressure Under Drug‐Induced Sleep Endoscopy. Otolaryngology–Head and Neck Surgery. 2024. doi:10.1002/ohn.730

BibTeX
@article{Chan2024,
  author = {Chan, Tyler G and Plageman, Jack and Yu, Jason L},
  title = {The Repeatability of Pharyngeal Opening Pressure Under Drug‐Induced Sleep Endoscopy},
  journal = {Otolaryngology–Head and Neck Surgery},
  year = {2024},
  doi = {10.1002/ohn.730}
}
Start for free →