Abstract (original language)

Objective

The purpose of this study is to compare initial low frequency hearing preservation (LFHP) in patients undergoing robotic‐assisted cochlear implantation (CI) to those undergoing manual CI. Study Design Retrospective review.

Setting

Tertiary referral center.

Methods

Adult CI patients with low‐frequency residual hearing, defined as a preoperative low‐frequency pure tone average (LFPTA) at 250 and 500 Hz ≤80 dB HL, were included in this study. Patients underwent either robotic‐assisted or manual CI. All implants utilized lateral wall electrodes. The primary outcomes were the change in LFPTA (ΔLFPTA) and the presence of LFHP, defined as ΔLFPTA ≤ 30 dB HL, following robotic‐assisted or manual CI.

Results

35 robotic‐assisted and 27 manual cases met the inclusion criteria for comparison of initial LFHP. The mean preoperative LFPTA was 56.14 and 62.04 dB HL ( P = .11) while the mean postoperative LFPTA was 88.86 and 91.02 dB HL for robotic‐assisted and manual insertion, respectively ( P = .63). The ΔLFPTA was not significantly different between the robotic‐assisted and manual insertion groups (32.17 dB HL robotic‐assisted vs 28.98 dB HL manual, P = .82). LFHP was similar between groups (57.10% robotic‐assisted vs 51.90% manual, P = .68).

Conclusion

There is no significant difference in initial LFHP between robotic‐assisted and manual CI in this study group, though robotic‐assisted insertion may still offer benefit for preservation of residual hearing over time. Further studies with longer follow‐up are needed to fully evaluate the impact of robotic‐assisted insertion on hearing preservation.

Subjects

Author keywords

cochlear implanthearing preservationrobotic cochlear implant

Authors and institutions

  • Department of Otolaryngology-Head and Neck Surgery, AdventHealth Celebration, Celebration, Florida, USA.
  • Department of Otolaryngology-Head and Neck Surgery, University of Central Florida College of Medicine, Orlando, Florida, USA.

ORCID profiles: Ilana Yellin

Cite

APA

Yellin, I., Jacob, N. M., Seidman, M. D., & Brownlee, A. (2026). Comparison of Cochlear Implant Hearing Outcomes Following Manual and Robotic Electrode Insertion. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.70522

Vancouver

Yellin I, Jacob NM, Seidman MD, Brownlee A. Comparison of Cochlear Implant Hearing Outcomes Following Manual and Robotic Electrode Insertion. Otolaryngology–Head and Neck Surgery. 2026. doi:10.1002/ohn.70522

BibTeX
@article{Yellin2026,
  author = {Yellin, Ilana and Jacob, Nathan M and Seidman, Michael D and Brownlee, ArielMae},
  title = {Comparison of Cochlear Implant Hearing Outcomes Following Manual and Robotic Electrode Insertion},
  journal = {Otolaryngology–Head and Neck Surgery},
  year = {2026},
  doi = {10.1002/ohn.70522}
}
Start for free →