Contrast Swallow for Detecting Pharyngocutaneous Fistula After Total Laryngectomy: A Systematic Review
Otolaryngology–Head and Neck Surgery · 2026-07 · 175 (1) · 39-48
DOI: 10.1002/ohn.70251 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Otolaryngology–Head and Neck Surgery, online erschienen am 04.05.2026. Verfasst von Matthew E Ryan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Liverpool Head & Neck Centre, Liverpool University Hospitals NHS Foundation Trust, Liverpool, L9 7AL, UK. Hauptthemen laut MEDLINE: Laryngectomy, Cutaneous Fistula, Pharyngeal Diseases, Contrast Media. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Objective
To evaluate the diagnostic performance of contrast swallow utilised to identify pharyngocutaneous fistula (PCF) following laryngectomy. Data Sources A systematic search of databases was conducted (MEDLINE, EMBASE, and PubMed). Review Methods Studies including adult patients (≥18 years old) who had undergone total laryngectomy (salvage or primary) or pharyngolaryngectomy and had postoperative diagnostic imaging of any modality (eg, ultrasound, CT, MRI) performed to assess for presence of PCF were eligible for inclusion. The diagnostic accuracy (ie sensitivity, specificity, etc.) for identifying PCF was extracted.
Results
A total of 13 studies involving 1456 patients recruited across a 43‐year period from (1979 to 2022) were included. Diagnostic accuracy ranges of contrast swallow were reported as a sensitivity of 0.26 to 1.00, specificity of 0.55 to 0.99 and positive and negative predictive values of 0.14 to 0.85 and 0.75 to 1.00 respectively.
Conclusions
The accuracy of contrast swallow as a screening tool in detecting PCF varies significantly in the reported studies with overall poor performance. Studies displayed a varied positive predictive value range, with a high number of false positives potentially causing unwarranted delays in commencing oral feeding. Positive predictive values must be interpreted cautiously given the literatures variation of how pharyngeal leaks were managed, potentially preventing progression to clinical PCF. While the heterogenicity within the data from the studies prevents definitive conclusions, the review calls into question the utility of the contrast swallow and highlights the need for more superior diagnostic pathways.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Liverpool Head & Neck Centre, Liverpool University Hospitals NHS Foundation Trust, Liverpool, L9 7AL, UK.
- School of Medicine, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, L69 3GE, UK.
- Department of Molecular and Clinical Cancer Medicine, Faculty of Health and Life Sciences, University of Liverpool, Liverpool, L69 7TX, UK.
ORCID-Profile: Matthew E Ryan, Kristijonas Milinis, Jason C Fleming
Zitieren
APA
Ryan, M. E., Milinis, K., Ahamed, M., Sidat, F. I., & Fleming, J. C. (2026). Contrast Swallow for Detecting Pharyngocutaneous Fistula After Total Laryngectomy: A Systematic Review. Otolaryngology–Head and Neck Surgery, 175(1), 39-48. https://doi.org/10.1002/ohn.70251
Vancouver
Ryan ME, Milinis K, Ahamed M, Sidat FI, Fleming JC. Contrast Swallow for Detecting Pharyngocutaneous Fistula After Total Laryngectomy: A Systematic Review. Otolaryngology–Head and Neck Surgery. 2026;175(1):39-48. doi:10.1002/ohn.70251
BibTeX
@article{Ryan2026,
author = {Ryan, Matthew E and Milinis, Kristijonas and Ahamed, Michael and Sidat, Faheema I and Fleming, Jason C},
title = {Contrast Swallow for Detecting Pharyngocutaneous Fistula After Total Laryngectomy: A Systematic Review},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2026},
volume = {175},
number = {1},
pages = {39--48},
doi = {10.1002/ohn.70251}
}
EUVIMED