Click SP/AP Area Ratio Vesrus Tone Burst SP Amplitude to Diagnose Ménière's Disease Using Electrocochleography
Otolaryngology–Head and Neck Surgery · 2024
DOI: 10.1002/ohn.693 ↗At a glance
Vergleichsstudie in Otolaryngology–Head and Neck Surgery, 2024. Written by Naif Bawazeer and 3 co-authors. Institution: Division of Otolaryngology-Head & Neck Surgery, University of Montreal, Montreal, Québec, Canada. Major MEDLINE topics: Meniere Disease, Audiometry, Evoked Response, Sensitivity and Specificity. Cited 6 times so far (Crossref); 31 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Objectives
To evaluate the sensitivity and the specificity of summating potential (SP)/action potential (AP) area under the curve (AUC) ratio by a transtympanic electrode and a click stimulus (TT‐CS), SP/AP AUC ratio by an extratympanic electrode and a click stimulus (ET‐CS) and SP amplitude value by a transtympanic electrode and tone burst stimulus (TT‐TBS) in regard of Ménière's disease (MD) diagnosis. This is the first study that compares SP amplitude value performed by a TT‐TBS and the SP/AP AUC ratio performed by a TT‐CS. Study Design Retrospective comparative study. Settings Ninety‐five patients met the inclusion criteria for electrocochleography (ECochG) testing in a tertiary care center.
Methods
The sensitivity and specificity of our different ECochG protocols were calculated in regard of the diagnosis of MD.
Results
The patients' mean age was 54 years old (female predominance). The sensitivity and the specificity of SP/AP area ratio by a TT‐CS were 88.5% and 70.0%, respectively. On the other hand, the sensitivity and specificity for the SP amplitude value by a TT‐TBS were 60.0% and 55.6%, respectively. SP/AP area ratio by TT‐CS was statistically better than SP amplitude value by TT‐TBS to detect MD disease ( P = .016). However, no difference was identified between SP/AP area ratio by ET‐CS and SP amplitude value by a TT‐TBS ( P = .573).
Conclusion
SP/AP area ratio by click stimulation has higher sensitivity and specificity to detect MD compared to SP amplitude value by tone burst stimulation. ECochG would be extremely useful in the diagnosis of MD if we use the SP/AP area ratio (sensitivity: 88.5%); therefore, it changes the bad reputation of ECochG sensitivity using SP/AP amplitude ratio (sensitivity: 51.7%) for the diagnosis of MD.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Division of Otolaryngology-Head & Neck Surgery, University of Montreal, Montreal, Québec, Canada.
- Faculty of Medicine, School of Speech Language Pathology and Audiology, University of Montreal, Montreal, Quebec, Canada.
- Research Theme: Neuroscience-Otology & Neurotology, University of Montreal Hospital Centre Research Centre (CRCHUM), Montreal, Québec, Canada.
- Department of Otolaryngology-Head & Neck Surgery, University of Montreal Hospital Centre (CHUM), Montreal, Québec, Canada.
Cite
APA
Bawazeer, N., Gagnon, C., Maheu, M., & Saliba, I. (2024). Click SP/AP Area Ratio Vesrus Tone Burst SP Amplitude to Diagnose Ménière's Disease Using Electrocochleography. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.693
Vancouver
Bawazeer N, Gagnon C, Maheu M, Saliba I. Click SP/AP Area Ratio Vesrus Tone Burst SP Amplitude to Diagnose Ménière's Disease Using Electrocochleography. Otolaryngology–Head and Neck Surgery. 2024. doi:10.1002/ohn.693
BibTeX
@article{Bawazeer2024,
author = {Bawazeer, Naif and Gagnon, Carolanne and Maheu, Maxime and Saliba, Issam},
title = {Click SP/AP Area Ratio Vesrus Tone Burst SP Amplitude to Diagnose Ménière's Disease Using Electrocochleography},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2024},
doi = {10.1002/ohn.693}
}