EUVIMEDOtkrijte EUVIMED
Crossref

Right Versus Left Cuff Position for Upper Airway Stimulation

Alexandra M Arambula, Antonio Bon-Nieves iD, Rahul Alapati, Johnny Wei, Sarah Wagoner, Amelia Lawrence, Bryan Renslo, David Rouse, Christopher Larsen

Otolaryngology–Head and Neck Surgery · 2024

DOI: 10.1002/ohn.668 ↗

At a glance

Journal article in Otolaryngology–Head and Neck Surgery, 2024. Written by Alexandra M Arambula and 8 co-authors. Institution: Department of Otolaryngology-Head and Neck Surgery, University of Kansas Medical Center, Kansas City, Kansas, USA. Major MEDLINE topics: Electric Stimulation Therapy, Larynx, Sleep Apnea, Obstructive. Cited 2 times so far (Crossref); 20 references.

SažetakSubjectsBibliografski podaciCiteRelated studies

Abstract (original language)

Objective

Upper airway stimulation (UAS) is a treatment option for obstructive sleep apnea in which electrical stimulation is applied to the hypoglossal nerve. Nerve branches that control tongue protrusion are located inferiorly. Due to positioning, left‐sided implants are typically placed with an inferiorly oriented electrode cuff (L‐down) as opposed to superiorly on the right (R‐up). In this study, we assess the impact of left‐ versus right‐sided UAS on patient outcomes. Study Design Retrospective cohort study.

Setting

Tertiary Academic Medical Center.

Methods

Patients who underwent UAS implantation between 2016 and 2021 with an L‐down or R‐up oriented cuff as confirmed by X‐ray were included. Data were collected retrospectively. Most recent sleep study variables were used for analysis.

Results

A total of 190 patients met the inclusion criteria. The average age was 61.0 ± 11.0 years, with 55 (28.9%) females. L‐down orientation was present in 21 (11.1%) patients vs 169 (88.9%) R‐up. Indications for L‐down included hunting/shooting (n = 15), prior radiation/surgery (n = 4), central port (n = 1), and brachial plexus injury (n = 1). Adherence was higher among L‐down patients (47.1 vs 41.0 hours use/week, P = .037) in univariate analysis, with a similar time to adherence data collection (4.4 vs 4.2 months, P = .612), though this finding was not maintained in the multivariate regression analysis. Decrease in apnea‐hypopnea index (21.3 vs 22.8, P = .734), treatment success (76.5% vs 84.0%, P = .665), functional threshold (1.5 vs 1.6, P = .550), therapeutic amplitude (2.3 vs 2.4, P = .882), and decrease in Epworth Sleepiness Scale (4.9 vs 2.6, P = .060) were not significantly different between cohorts.

Conclusion

This study is the first to examine the orientation of the UAS electrode cuff concerning the electrodes' natural position and the potential effect on postoperative outcomes. Our study found no significantly different treatment outcomes between the L‐down versus R‐up cohort, with the exception of device adherence, which was significantly higher in the L‐down group on univariate analysis though not on multivariate analysis. Future studies with larger patient cohorts are needed to further investigate this potential relationship between treatment outcomes and electrode cuff orientation.

Subjects

MeSH terms (MEDLINE)

Electric Stimulation TherapyLarynxSleep Apnea, ObstructiveFemaleHumansMiddle AgedAgedMaleRetrospective StudiesNoseTreatment OutcomeHypoglossal Nerve

Author keywords

adherenceobstructive sleep apneaupper airway stimulation

Authors and institutions

  • Department of Otolaryngology-Head and Neck Surgery, University of Kansas Medical Center, Kansas City, Kansas, USA.
  • Department of Otolaryngology-Head and Neck Surgery, Case Western Reserve University/University Hospitals, Cleveland, Ohio, USA.
  • Department of Anesthesiology, University of Kansas Medical Center, Kansas City, Kansas, USA.
  • Department of Anesthesiology, Vanderbilt University Medical Center, Nashville, Tennessee, USA.
  • Department of Otolaryngology-Head and Neck Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.

ORCID profiles: Antonio Bon-Nieves

Cite

APA

Arambula, A. M., Bon-Nieves, A., Alapati, R., Wei, J., Wagoner, S., Lawrence, A., Renslo, B., Rouse, D., & Larsen, C. (2024). Right Versus Left Cuff Position for Upper Airway Stimulation. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.668

Vancouver

Arambula AM, Bon-Nieves A, Alapati R, Wei J, Wagoner S, Lawrence A, et al. Right Versus Left Cuff Position for Upper Airway Stimulation. Otolaryngology–Head and Neck Surgery. 2024. doi:10.1002/ohn.668

BibTeX
@article{Arambula2024,
  author = {Arambula, Alexandra M and Bon-Nieves, Antonio and Alapati, Rahul and Wei, Johnny and Wagoner, Sarah and Lawrence, Amelia and Renslo, Bryan and Rouse, David and Larsen, Christopher},
  title = {Right Versus Left Cuff Position for Upper Airway Stimulation},
  journal = {Otolaryngology–Head and Neck Surgery},
  year = {2024},
  doi = {10.1002/ohn.668}
}
Start for free →