EUVIMEDTutustu EUVIMEDiin
Systematische ÜbersichtMetaanalyse

Efficacy and Safety of Lasers in Treating Head and Neck Capillary Malformations: A Systematic Review and Meta‐analysis

Soroush Farsi, Peter Eckard iD, Walker Bartels, Peyton Pinkus, Gresham T Richter

Otolaryngology–Head and Neck Surgery · 2025

DOI: 10.1002/ohn.1309 ↗

At a glance

Systematische Übersicht in Otolaryngology–Head and Neck Surgery, 2025. Written by Soroush Farsi and 4 co-authors. Institution: Department of Otolaryngology-Head and Neck Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA. Major MEDLINE topics: Neck, Laser Therapy, Vascular Malformations, Lasers, Solid-State. 31 references.

TiivistelmäSubjectsBibliografiset tiedotCiteRelated studies

Abstract (original language)

Objective

This study aims to comprehensively review and compare the safety and efficacy of commonly used lasers in the management of head and neck capillary malformations (CMs). Data Sources PubMed, Embase, Cochrane, and Web of Science. Review Methods Databases were searched from inception to August 2023. Study protocols adhered to the PRISMA guidelines. Cohort studies reporting CM laser treatment outcomes were included. Study validity was tested using the Newcastle‐Ottawa Scale. Meta‐analysis was conducted using the inverse variance method and a fixed effects model, with treatment success defined as achieving 25% to 100% clearance of the lesion.

Results

A total of 725 studies were screened, and 14 full‐text articles met the criteria, comprising 714 patients. Patients underwent a mean of 6.5 laser treatment sessions, consisting of 80% pulsed dye laser (PDL), 12% neodymium‐doped yttrium‐aluminum‐garnet laser (Nd:YAG), and 8% 577 nm yellow laser treatments. Meta‐analysis revealed an overall treatment success rate of 97% (95% confidence interval [CI]: 0.96‐0.98). Subgroup analysis by laser type resulted a success rate of 96% (95% CI: 0.94‐0.973) for PDL, 99% (95% CI: 0.979‐1.008) for Nd:YAG laser, and 86% (95% CI: 0.7621‐0.964) for 577 nm yellow laser. The complication rate by laser type was 9% (95% CI: 0.031‐0.147) for PDL, 4% (95% CI: 0.007‐0.080) for Nd:YAG laser, and no reported complication data for 577 nm yellow laser.

Conclusion

The vast majority of the available data on laser treatment of head and neck CMs suggest excellent outcomes and low complication rate using PDL treatment. Centers using Nd:YAG laser reported a slightly higher rate of successful treatment with fewer complications than PDL or 577 nm yellow laser treatment.

Subjects

MeSH terms (MEDLINE)

NeckLaser TherapyVascular MalformationsLasers, Solid-StateHeadCapillariesLasers, DyeHumansTreatment Outcome

Author keywords

Nd:YAG laserPDLPWSport‐wine stainpulsed dye laservascular malformationsyellow laser

Authors and institutions

  • Department of Otolaryngology-Head and Neck Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA.
  • Department of Otolaryngology-Head and Neck Surgery, Arkansas Children's Hospital, Little Rock, Arkansas, USA.

ORCID profiles: Peter Eckard

Cite

APA

Farsi, S., Eckard, P., Bartels, W., Pinkus, P., & Richter, G. T. (2025). Efficacy and Safety of Lasers in Treating Head and Neck Capillary Malformations: A Systematic Review and Meta‐analysis. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.1309

Vancouver

Farsi S, Eckard P, Bartels W, Pinkus P, Richter GT. Efficacy and Safety of Lasers in Treating Head and Neck Capillary Malformations: A Systematic Review and Meta‐analysis. Otolaryngology–Head and Neck Surgery. 2025. doi:10.1002/ohn.1309

BibTeX
@article{Farsi2025,
  author = {Farsi, Soroush and Eckard, Peter and Bartels, Walker and Pinkus, Peyton and Richter, Gresham T},
  title = {Efficacy and Safety of Lasers in Treating Head and Neck Capillary Malformations: A Systematic Review and Meta‐analysis},
  journal = {Otolaryngology–Head and Neck Surgery},
  year = {2025},
  doi = {10.1002/ohn.1309}
}
Start for free →