Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta‐Analysis
Otolaryngology–Head and Neck Surgery · 2025
DOI: 10.1002/ohn.1167 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Otolaryngology–Head and Neck Surgery, 2025. Verfasst von Andrea Costantino und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology-Head and Neck Surgery, AdventHealth Orlando, Orlando, Florida, United States. Hauptthemen laut MEDLINE: Anastomosis, Surgical, Free Tissue Flaps, Head and Neck Neoplasms, Microsurgery. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 76 Literaturangaben.
Abstract (Originalsprache)
Objective
We conducted a systematic review and meta‐analysis to compare venous couplers and hand‐sewn techniques for venous anastomosis in head and neck reconstruction. Data Sources PubMed/MEDLINE and Scopus, databases were searched for relevant publications. Additionally, a manual search was performed in Google Scholar and through reference lists. Review Methods Retrospective and prospective cohort studies were included. Odds ratios (ORs) and mean differences (MD) were calculated with their 95% confidence intervals (CIs) for each study comparing the 2 groups (coupler vs hand). The inverse variance method was used to combine the effect sizes from the individual studies.
Results
A total of 14,053 patients undergoing 14,270 head and neck free flap reconstructions were included from 52 studies. A total of 6080 flaps were performed using a coupling device for the venous anastomoses, while 8190 flaps were performed with the hand‐sewn technique. No significant difference was found for the venous thrombosis rate (OR: 1.06, 95% CI: 0.65‐1.72), and reoperation rate (OR: 0.93, 95% CI: 0.51‐1.70), but a significantly lower failure rate was measured for the coupler group (OR = 0.34, 95% CI: 0.20‐0.58). A nonsignificant lower operative time was found for venous anastomoses (MD: −20.5, 95% CI: −51.7 to 10.7) and total surgery (MD: −23.7, 95% CI: −344.3 to 296.8) for the coupler group.
Conclusion
Despite the slight advantages observed with venous couplers, the overall outcomes of both techniques are excellent, and the choice of anastomotic technique should be guided by surgeon preference.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Otolaryngology-Head and Neck Surgery, AdventHealth Orlando, Orlando, Florida, United States.
- Department of Biomedical Sciences, Humanitas University, Milan, Italy.
- Otorhinolaryngology Unit, IRCCS Humanitas Research Hospital, Milan, Italy.
- Department of Otolaryngology-Head and Neck Surgery, University of South Florida Morsani College of Medicine, Tampa, Florida, USA.
- Department of Surgery, University of Auckland School of Medicine and Allied Health Sciences, Auckland, New Zealand.
- Department of 'Organi di Senso', Sapienza University, Rome, Italy.
ORCID-Profile: Andrea Costantino, Bianca Maria Festa
Zitieren
APA
Costantino, A., Uralov, D., Festa, B. M., Pace, G. M., Alamoudi, U., Haughey, B., Iannella, G., Greco, A., Magnuson, J. S., & De Virgilio, A. (2025). Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta‐Analysis. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1002/ohn.1167
Vancouver
Costantino A, Uralov D, Festa BM, Pace GM, Alamoudi U, Haughey B, et al. Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta‐Analysis. Otolaryngology–Head and Neck Surgery. 2025. doi:10.1002/ohn.1167
BibTeX
@article{Costantino2025,
author = {Costantino, Andrea and Uralov, Daniel and Festa, Bianca Maria and Pace, Gian Marco and Alamoudi, Uthman and Haughey, Bruce and Iannella, Giannicola and Greco, Antonio and Magnuson, J Scott and De Virgilio, Armando},
title = {Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta‐Analysis},
journal = {Otolaryngology–Head and Neck Surgery},
year = {2025},
doi = {10.1002/ohn.1167}
}
EUVIMED