Comparison of a coupling system and the suture method in end‐to‐side microvascular anastomosis in head and neck reconstruction
Microsurgery · 2024
DOI: 10.1002/micr.31160 ↗Kurz gefasst
Fallbericht in der Zeitschrift Microsurgery, 2024. Verfasst von Seong Ae Kim und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Plastic and Reconstructive Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Kore…. Hauptthemen laut MEDLINE: Plastic Surgery Procedures, Head and Neck Neoplasms, Free Tissue Flaps. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Background
Use of coupling devices in microvascular anastomosis continues to increase, but it is not yet actively used in end‐to‐side (ETS) anastomosis because there is no standard method. Therefore, we propose an easy and time‐saving ETS micro‐anastomosis method using coupling devices in head and neck reconstruction and compare it with the conventional suture method. Materials and Methods We retrospectively reviewed 30 consecutive cases (43 anastomoses) of ETS anastomosis in head and neck reconstruction from 2018 to 2022. Patient characteristics, operative details, and anastomosis time were evaluated. When using the coupling device, a cross incision was created in the recipient vessel to form vascular flaps. By pulling the flaps out of the ring, the intact vessel lining was fixed. Other procedures were the same as for a traditional anastomosis.
Results
The mean anastomosis time was 12.81 min (range, 6.7–24.87) for the suture and 4.96 min (range, 2.02–9.4) for the coupling device, a statistically significant difference ( p ‐value
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Plastic and Reconstructive Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea.
ORCID-Profile: Seong Ae Kim, Deuk Young Oh, Young-Joon Jun, Suk-Ho Moon
Zitieren
APA
Kim, S. A., Kim, J., Lee, C. R., Oh, D. Y., Jun, Y. J., & Moon, S. H. (2024). Comparison of a coupling system and the suture method in end‐to‐side microvascular anastomosis in head and neck reconstruction. Microsurgery. https://doi.org/10.1002/micr.31160
Vancouver
Kim SA, Kim J, Lee CR, Oh DY, Jun YJ, Moon SH. Comparison of a coupling system and the suture method in end‐to‐side microvascular anastomosis in head and neck reconstruction. Microsurgery. 2024. doi:10.1002/micr.31160
BibTeX
@article{Kim2024,
author = {Kim, Seong Ae and Kim, Junnyeon and Lee, Chae Rim and Oh, Deuk Young and Jun, Young-Joon and Moon, Suk-Ho},
title = {Comparison of a coupling system and the suture method in end‐to‐side microvascular anastomosis in head and neck reconstruction},
journal = {Microsurgery},
year = {2024},
doi = {10.1002/micr.31160}
}