Evaluating the “2cm2kg” Target in Japan's Specific Health Checkups: Evidence From the Panasonic Cohort Study 30
Obesity · 2026-05 · 34 (5) · 1020-1031
DOI: 10.1002/oby.70186 ↗At a glance
Kohortenstudie in Obesity, published online on 2026-04-04. Written by Kenya Kasahara and 13 co-authors. Institution: Department of Endocrinology and Metabolism, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan. Major MEDLINE topics: Waist Circumference, Weight Loss, Obesity, Body Weight. 38 references.
Abstract (original language)
Objective
The national Specific Health Checkups and Guidance program set a “2 cm waist circumference (WC) and 2 kg body weight (BW) reduction” (2cm2kg) target in Japan. This study aimed to examine the validity of the 2cm2kg target.
Methods
We analyzed data from the Panasonic cohort study of adults ≥ 40 years undergoing health checkups in 2020. Anthropometrics, glucose, blood pressure (BP), lipids, and liver function were measured at baseline and 1 year. Achievement of 2cm2kg was defined as ≥ 2 cm WC and ≥ 2 kg BW reductions. Analyses included covariance, logistic regression, spline, and receiver operating characteristic analyses.
Results
Among 30,240 participants, the aim of 2cm2kg achieved reductions of over 5 cm in WC and 5 kg in BW. This was significantly associated with improvements in multiple metabolic indicators—including triglycerides, low‐density lipoprotein cholesterol, BP, liver function, and high‐density lipoprotein cholesterol (all p < 0.0001). Greater reductions in WC and BW yielded larger, consistent benefits across subgroups by sex, age ≥ 50, and baseline medication use. Cutoff values predicting metabolic improvements were generally −1 to −2 cm WC and −1 to −2 kg BW, and spline analyses showed monotonic improvements with greater WC and BW reductions.
Conclusions
Reductions ≥ 2cm2kg were associated with metabolic improvements in Specific Health Checkups and Guidance‐eligible individuals.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Endocrinology and Metabolism, Kyoto Prefectural University of Medicine, Graduate School of Medical Science, Kyoto, Japan.
- Institute for Future Initiatives, The University of Tokyo, Tokyo, Japan.
- Department of Health Care Center, Panasonic Health Insurance Organization, Moriguchi, Japan.
- Department of Orthopedic Surgery, Matsushita Memorial Hospital, Moriguchi, Japan.
ORCID profiles: Kenya Kasahara, Hiroshi Okada, Hanako Nakajima, Masahide Hamaguchi
Cite
APA
Kasahara, K., Okada, H., Ide, H., Nakajima, H., Ushigome, E., Nakanishi, N., Hamaguchi, M., Kurogi, K., Murata, H., Tsuda, E., Yoshida, N., Ito, M., Furui, Y., & Fukui, M. (2026). Evaluating the “2cm2kg” Target in Japan's Specific Health Checkups: Evidence From the Panasonic Cohort Study 30. Obesity, 34(5), 1020-1031. https://doi.org/10.1002/oby.70186
Vancouver
Kasahara K, Okada H, Ide H, Nakajima H, Ushigome E, Nakanishi N, et al. Evaluating the “2cm2kg” Target in Japan's Specific Health Checkups: Evidence From the Panasonic Cohort Study 30. Obesity. 2026;34(5):1020-1031. doi:10.1002/oby.70186
BibTeX
@article{Kasahara2026,
author = {Kasahara, Kenya and Okada, Hiroshi and Ide, Hiroo and Nakajima, Hanako and Ushigome, Emi and Nakanishi, Naoko and Hamaguchi, Masahide and Kurogi, Kazushiro and Murata, Hiroaki and Tsuda, Eri and Yoshida, Naoki and Ito, Masato and Furui, Yuji and Fukui, Michiaki},
title = {Evaluating the “2cm2kg” Target in Japan's Specific Health Checkups: Evidence From the Panasonic Cohort Study 30},
journal = {Obesity},
year = {2026},
volume = {34},
number = {5},
pages = {1020--1031},
doi = {10.1002/oby.70186}
}
EUVIMED