EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity

John C Lin, Clara E Tandar iD, Simar S Bajaj iD, Fatima C Stanford iD

Obesity · 2026

DOI: 10.1002/oby.70150 ↗

At a glance

Journal article in Obesity, 2026. Written by John C Lin and 3 co-authors. Institution: Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Major MEDLINE topics: Waist Circumference, Body Mass Index, Adiposity, Obesity. Cited 5 times so far (Crossref); 17 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIH HHS, National Institutes of Health.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objective

This study compared the diagnostic performance of BMI, waist circumference (WC), and Lancet Commission (LC) criteria for assessing excess adiposity measured by dual‐energy X‐ray absorptiometry (DEXA) in US adults.

Methods

Using 2011–2018 NHANES data, we included 10,747 adults aged 20–59 years with relevant data. We evaluated the diagnostic performance (sensitivity, specificity, positive and negative predictive values [PPV, NPV], area under the curve [AUC]) of BMI thresholds, waist‐based measures, and LC criteria for excess adiposity, as defined by DEXA.

Results

The weighted prevalence of DEXA‐defined excess adiposity was 36.4%. CDC BMI thresholds demonstrated 74.6% sensitivity and 82.2% specificity (PPV, 67.0%; NPV, 87.0%). Waist‐based measures showed higher sensitivity and lower specificity than BMI; NHLBI WC thresholds produced 88.5% sensitivity and 66.7% specificity. LC criteria performed variably: BMI plus ≥ 1 waist measure had 74.6% sensitivity and 82.2% specificity, whereas ≥ 2 waist measures had 88.5% sensitivity and 66.8% specificity. The AUC values were 0.876 for BMI, 0.882 for WC, 0.887 for waist to height ratio, and 0.715 for waist to hip ratio.

Conclusions

Waist‐based definitions were more sensitive than BMI, whereas BMI provided greater specificity. LC criteria performed comparably to existing definitions. Incorporating WC into screening may improve the detection of excess adiposity.

Subjects

MeSH terms (MEDLINE)

Waist CircumferenceBody Mass IndexAdiposityObesityHumansAdultAbsorptiometry, PhotonFemaleMiddle AgedMaleSensitivity and SpecificityNutrition SurveysYoung AdultUnited States

Authors and institutions

  • Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Warren Alpert Medical School, Brown University, Providence, Rhode Island, USA.
  • Stanford University School of Medicine, Stanford, California, USA.
  • Neuroendocrine Unit, Nutrition Obesity Research Center (NORCH), MGH Weight Center, Massachusetts General Hospital, Boston, Massachusetts, USA.
  • Departments of Medicine and Pediatrics, Harvard Medical School, Harvard University, Boston, Massachusetts, USA.

ORCID profiles: Clara E Tandar, Simar S Bajaj, Fatima C Stanford

Funding

  • NIH HHS
  • National Institutes of Health

Cite

APA

Lin, J. C., Tandar, C. E., Bajaj, S. S., & Stanford, F. C. (2026). Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity. Obesity. https://doi.org/10.1002/oby.70150

Vancouver

Lin JC, Tandar CE, Bajaj SS, Stanford FC. Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity. Obesity. 2026. doi:10.1002/oby.70150

BibTeX
@article{Lin2026,
  author = {Lin, John C and Tandar, Clara E and Bajaj, Simar S and Stanford, Fatima C},
  title = {Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity},
  journal = {Obesity},
  year = {2026},
  doi = {10.1002/oby.70150}
}