Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity
Obesity · 2026
DOI: 10.1002/oby.70150 ↗Kurz gefasst
Fachartikel in der Zeitschrift Obesity, 2026. Verfasst von John C Lin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Waist Circumference, Body Mass Index, Adiposity, Obesity. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Objective
This study compared the diagnostic performance of BMI, waist circumference (WC), and Lancet Commission (LC) criteria for assessing excess adiposity measured by dual‐energy X‐ray absorptiometry (DEXA) in US adults.
Methods
Using 2011–2018 NHANES data, we included 10,747 adults aged 20–59 years with relevant data. We evaluated the diagnostic performance (sensitivity, specificity, positive and negative predictive values [PPV, NPV], area under the curve [AUC]) of BMI thresholds, waist‐based measures, and LC criteria for excess adiposity, as defined by DEXA.
Results
The weighted prevalence of DEXA‐defined excess adiposity was 36.4%. CDC BMI thresholds demonstrated 74.6% sensitivity and 82.2% specificity (PPV, 67.0%; NPV, 87.0%). Waist‐based measures showed higher sensitivity and lower specificity than BMI; NHLBI WC thresholds produced 88.5% sensitivity and 66.7% specificity. LC criteria performed variably: BMI plus ≥ 1 waist measure had 74.6% sensitivity and 82.2% specificity, whereas ≥ 2 waist measures had 88.5% sensitivity and 66.8% specificity. The AUC values were 0.876 for BMI, 0.882 for WC, 0.887 for waist to height ratio, and 0.715 for waist to hip ratio.
Conclusions
Waist‐based definitions were more sensitive than BMI, whereas BMI provided greater specificity. LC criteria performed comparably to existing definitions. Incorporating WC into screening may improve the detection of excess adiposity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
- Warren Alpert Medical School, Brown University, Providence, Rhode Island, USA.
- Stanford University School of Medicine, Stanford, California, USA.
- Neuroendocrine Unit, Nutrition Obesity Research Center (NORCH), MGH Weight Center, Massachusetts General Hospital, Boston, Massachusetts, USA.
- Departments of Medicine and Pediatrics, Harvard Medical School, Harvard University, Boston, Massachusetts, USA.
ORCID-Profile: Clara E Tandar, Simar S Bajaj, Fatima C Stanford
Förderung
- NIH HHS
- National Institutes of Health
Zitieren
APA
Lin, J. C., Tandar, C. E., Bajaj, S. S., & Stanford, F. C. (2026). Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity. Obesity. https://doi.org/10.1002/oby.70150
Vancouver
Lin JC, Tandar CE, Bajaj SS, Stanford FC. Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity. Obesity. 2026. doi:10.1002/oby.70150
BibTeX
@article{Lin2026,
author = {Lin, John C and Tandar, Clara E and Bajaj, Simar S and Stanford, Fatima C},
title = {Diagnostic Performance of BMI and Waist Circumference in Detecting Excess Adiposity},
journal = {Obesity},
year = {2026},
doi = {10.1002/oby.70150}
}
EUVIMED