Improved visualization of cochlear implant electrodes on photon counting detector CT

Dane G. Schroeder, Paul J. Farnsworth, Carrie M. Carr, David R. DeLone, John C. Benson, Matthew L. Carlson, Shuai Leng, Ian T. Mark, Blake A. Kassmeyer, Jack I. Lane

Clinical Neuroimaging · 2024

DOI: 10.1002/neo2.70005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Neuroimaging, 2024. Verfasst von Dane G. Schroeder und 9 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cochlear implants (CIs) are used to rehabilitate moderate to profound sensorineural hearing loss and stimulate the auditory system via a multichannel electrode array positioned in the scala tympani. Imaging evaluation of CIs is substantially degraded by metallic artifacts. Photon‐counting detector (PCD)‐CT has the potential to minimize such artifacts, though this has not been convincingly established in prior studies. This study compared the visualization of CI electrodes on PCD‐CT to conventional energy integrating detector (EID)‐CT. Materials and Methods Five patients with CIs were prospectively recruited to undergo temporal bone imaging on both EID‐CT and PCD‐CT scanners yielding 2D and 3D Volume Rendering Technique (VRT) images. Three nonblinded neuroradiologists reviewed 2D and 3D VRT images for the ability to resolve CI electrode leads using a Likert scale. The average Likert scores of PCD‐CT versus EID‐CT were calculated for each reader for both 2D and 3D VRT images. (Likert scores 1–5 based on inferior to superior rating of PCD‐CT compared to EID‐CT). Inter‐rater agreement was assessed using Krippendorff's alpha with ordinal weights.

Results

Five patients underwent temporal bone CT for CI array evaluation. As evidenced by 5‐point Likert scales that were independently used by the three reviewers, this study demonstrated superior resolution of CI electrode array using PCD‐CT as compared to EID‐CT with an average score of 4.2 ± 0.8 for 2D images and 4.9 ± 0.4 for 3D VRT images.

Conclusions

PCD‐CT is superior to EID‐CT in the visualization of CI electrodes, particularly in 3D VRT imaging.

Zitieren

APA

Schroeder, D. G., Farnsworth, P. J., Carr, C. M., DeLone, D. R., Benson, J. C., Carlson, M. L., Leng, S., Mark, I. T., Kassmeyer, B. A., & Lane, J. I. (2024). Improved visualization of cochlear implant electrodes on photon counting detector CT. Clinical Neuroimaging. https://doi.org/10.1002/neo2.70005

Vancouver

Schroeder DG, Farnsworth PJ, Carr CM, DeLone DR, Benson JC, Carlson ML, et al. Improved visualization of cochlear implant electrodes on photon counting detector CT. Clinical Neuroimaging. 2024. doi:10.1002/neo2.70005

BibTeX
@article{Schroeder2024,
  author = {Schroeder, Dane G. and Farnsworth, Paul J. and Carr, Carrie M. and DeLone, David R. and Benson, John C. and Carlson, Matthew L. and Leng, Shuai and Mark, Ian T. and Kassmeyer, Blake A. and Lane, Jack I.},
  title = {Improved visualization of cochlear implant electrodes on photon counting detector CT},
  journal = {Clinical Neuroimaging},
  year = {2024},
  doi = {10.1002/neo2.70005}
}
Kostenlos starten →