EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Technical Feasibility of IVIM for Prostate Cancer Imaging Using High‐Amplitude Whole‐Body Gradient System With Spiral Readout and Velocity‐Compensated Diffusion Encoding

Malwina Molendowska iD, Ivan A Rashid iD, Kieran Foley iD, Lars Mueller iD, Lars E Olsson iD, Patrik Brynolfsson iD, Filip Szczepankiewicz iD

NMR in Biomedicine · 2026

DOI: 10.1002/nbm.70384 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2026. Verfasst von Malwina Molendowska und 6 weiteren Autor:innen. Beteiligte Einrichtung: Medical Radiation Physics, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Diffusion Magnetic Resonance Imaging, Whole Body Imaging. Die Arbeit nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Cancer Research Wales Innovation Grant, EPSRC equipment, Wellcome Trust Strategic Awards.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intravoxel incoherent motion (IVIM) is sensitive to tissue diffusion and perfusion and has spurred great interest in various pathologies such as prostate cancer. However, poor repeatability and reproducibility of IVIM parameters hamper its wide‐scale adoption in the clinics. To address this, improvements to the IVIM data acquisition and analysis are necessary. The purpose of this study was to develop a framework for high‐quality IVIM imaging of the prostate. To boost signal precision and quality of IVIM parameter maps, we used a custom pulse sequence to combine velocity‐compensated diffusion encoding with spiral readout at a high‐performance 3 T MRI system with 300 mT/m gradients. IVIM parameters were evaluated in a cohort of five men with and without prostate cancer. Technical performance was assessed in terms of the signal‐to‐noise ratio (SNR), visual quality of IVIM parameter maps and parameter repeatability. High in‐plane resolution images of the prostate were obtained with SNR > 3 (i.e., noise floor level) in 91% of voxels at the highest b‐value of 500 s/mm 2 . The parameter maps exhibited high quality with fine features recovered in tissue diffusivity and perfusion fraction maps. Voxel‐wise and ROI‐based analysis revealed high repeatability of the parameters at single subject and group level across main prostatic tissue classes (peripheral and transitional zones) and prostate cancer. A combination of velocity‐compensated diffusion encoding, spiral readout and strong gradients enables high‐quality IVIM imaging in the prostate. Our framework may advance IVIM as a reliable imaging biomarker in prostate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsDiffusion Magnetic Resonance ImagingWhole Body ImagingHumansMaleFeasibility StudiesSignal-To-Noise RatioReproducibility of ResultsMotionDiffusionMiddle AgedAged

Stichwörter der Autor:innen

IVIMperfusionprostate cancerstrong gradientsvelocity compensation

Autor:innen und Institutionen

  • Medical Radiation Physics, Lund University, Lund, Sweden.
  • Cardiff University Brain Research Imaging Centre (CUBRIC), Cardiff University, Cardiff, UK.
  • Department of Translational Medicine, Medical Radiation Physics, Lund University, Malmo, Sweden.
  • Division of Cancer and Genetics, School of Medicine, Cardiff University, Cardiff, UK.
  • Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skane University Hospital, Lund, Sweden.

ORCID-Profile: Malwina Molendowska, Ivan A Rashid, Kieran Foley, Lars Mueller, Lars E Olsson, Patrik Brynolfsson, Filip Szczepankiewicz

Förderung

  • Cancer Research Wales Innovation Grant
  • EPSRC equipment
  • Wellcome Trust Strategic Awards
  • Royal College of Radiologists Pump Priming Grant
  • Kungliga Fysiografiska Sällskapet
  • Wellcome Trust Investigator Award
  • Cancerfonden
  • Crafoordska Stiftelsen

Zitieren

APA

Molendowska, M., Rashid, I. A., Foley, K., Mueller, L., Olsson, L. E., Brynolfsson, P., & Szczepankiewicz, F. (2026). Technical Feasibility of IVIM for Prostate Cancer Imaging Using High‐Amplitude Whole‐Body Gradient System With Spiral Readout and Velocity‐Compensated Diffusion Encoding. NMR in Biomedicine. https://doi.org/10.1002/nbm.70384

Vancouver

Molendowska M, Rashid IA, Foley K, Mueller L, Olsson LE, Brynolfsson P, et al. Technical Feasibility of IVIM for Prostate Cancer Imaging Using High‐Amplitude Whole‐Body Gradient System With Spiral Readout and Velocity‐Compensated Diffusion Encoding. NMR in Biomedicine. 2026. doi:10.1002/nbm.70384

BibTeX
@article{Molendowska2026,
  author = {Molendowska, Malwina and Rashid, Ivan A and Foley, Kieran and Mueller, Lars and Olsson, Lars E and Brynolfsson, Patrik and Szczepankiewicz, Filip},
  title = {Technical Feasibility of IVIM for Prostate Cancer Imaging Using High‐Amplitude Whole‐Body Gradient System With Spiral Readout and Velocity‐Compensated Diffusion Encoding},
  journal = {NMR in Biomedicine},
  year = {2026},
  doi = {10.1002/nbm.70384}
}
Kostenlos starten →