Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla
NMR in Biomedicine · 2026
DOI: 10.1002/nbm.70380 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2026. Verfasst von Karen N van der Werff und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands. Hauptthemen laut MEDLINE: Contrast Media, Microvessels, Magnetic Resonance Imaging, Spin Labels. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nederlandse Organisatie voor Wetenschappelijk Onderzoek.
Abstract (Originalsprache)
Perfusion MRI, especially dynamic susceptibility contrast (DSC), is vital for glioma diagnosis and monitoring. While gradient‐echo DSC is the current recommended implementation, combined spin‐ and gradient‐echo (SAGE) DSC additionally allows for vessel size imaging (VSI) and has shown feasibility for microvascular characterization at 3 T. Higher field strength MRI offers increased contrast, resolution and signal‐to‐noise ratio, providing potential to improve microvascular characterization. This feasibility study aimed to implement a protocol for SAGE‐DSC at 7 T and study its potential for microvascular characterization. SAGE‐DSC was acquired in eight patients undergoing treatment for glioma (four females, median age 57 years) at 3 and 7 T. Data were analyzed using the temporal signal‐to‐noise ratio (tSNR) and contrast‐to‐noise ratio (CNR) and by comparing perfusion maps, VSI and vascular architectural imaging (VAI). Simulations were performed to study the relationship between vessel size and for SAGE‐DSC at 3 and 7 T. Contrast agent dosage could be reduced while maintaining higher CNR at 7 T (but lower tSNR). Assessment by an experienced neuroradiologist showed similar rCBV map quality at 3 and 7 T. VSI maps showed the same normal‐appearing gray‐to‐white matter ratios while in‐plane resolution improved at least 52% at 7 T. VAI hysteresis loops at both field strengths traversed the same counter‐clockwise direction, with increased loop areas reflecting increased susceptibility effects at 7 T. Simulations confirmed the higher sensitivity of gradient‐echo and the higher specificity of spin‐echo to the microvasculature, with peak spin‐echo specificity moving from 3 μm at 3 T towards 1.5 μm at 7 T. This study confirmed the feasibility of using SAGE‐DSC at 7 T for microvascular characterization. rCBV and VSI maps show similar behavior while allowing for reduced contrast agent dosage and improved resolution. The spin‐echo specificity shifted towards smaller vessel radii for increasing field strengths. These findings form the basis for exploration and validation in larger patient populations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
- TU Delft, Department of Imaging Physics, Delft, the Netherlands.
- Medical Delta, Delft, the Netherlands.
- C. J. Gorter MRI Center, Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands.
- Brain Tumor Center, Erasmus MC Cancer Institute, Rotterdam, the Netherlands.
- Department of Cancer Systems Imaging, University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
ORCID-Profile: Karen N van der Werff, Daniëlle van Dorth, Esther A H Warnert, Dirk H J Poot, Frans M Vos, Marion Smits, Stefan Klein, Juan A Hernandez-Tamames, Johan A F Koekkoek, Matthias J P van Osch
Förderung
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
Zitieren
APA
van der Werff, K. N., van Dorth, D., Venugopal, K., Warnert, E. A. H., Poot, D. H. J., Vos, F. M., Smits, M., Klein, S., Quarles, C. C., Hernandez-Tamames, J. A., Koekkoek, J. A. F., de Bresser, J., & van Osch, M. J. P. (2026). Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla. NMR in Biomedicine. https://doi.org/10.1002/nbm.70380
Vancouver
van der Werff KN, van Dorth D, Venugopal K, Warnert EAH, Poot DHJ, Vos FM, et al. Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla. NMR in Biomedicine. 2026. doi:10.1002/nbm.70380
BibTeX
@article{vanderWerff2026,
author = {van der Werff, Karen N and van Dorth, Daniëlle and Venugopal, Krishnapriya and Warnert, Esther A H and Poot, Dirk H J and Vos, Frans M and Smits, Marion and Klein, Stefan and Quarles, C Chad and Hernandez-Tamames, Juan A and Koekkoek, Johan A F and de Bresser, Jeroen and van Osch, Matthias J P},
title = {Feasibility of Spin‐ and Gradient‐Echo Dynamic Susceptibility Contrast MRI for Microvascular Characterization at 7 Tesla},
journal = {NMR in Biomedicine},
year = {2026},
doi = {10.1002/nbm.70380}
}
EUVIMED