EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T

Shane A Wells iD, Giulia M Ippolito iD, Melis Ozkan iD, Wilson Sui iD, Anne P Cameron iD, Jesse I Hamilton iD

NMR in Biomedicine · 2026-09 · 39 (9)

DOI: 10.1002/nbm.70366 ↗

At a glance

Journal article in NMR in Biomedicine, published online on 2026-07-28. Written by Shane A Wells and 5 co-authors. Institution: Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA. Major MEDLINE topics: Urinary Bladder, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Healthy Volunteers. 54 references. The full text is freely available (open access, CC BY 4.0). Funded by: NHLBI NIH HHS, NIDDK NIH HHS, Siemens Healthineers.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Current diagnostic tests for lower urinary tract symptoms (LUTS) do not assess tissue‐level alterations in the bladder wall. This study assesses the feasibility of 3D magnetic resonance fingerprinting (MRF) for simultaneous T 1 , T 2 , and proton density (M 0 ) mapping of the bladder wall in healthy subjects at 1.5 T and 3 T. A 3D MRF acquisition was combined with a deep image prior reconstruction to achieve whole‐bladder T 1 , T 2 , and M 0 mapping in 11.8 min at an acquired voxel size of 1 × 1 × 3 mm 3 (interpolated to 0.5 × 0.5 × 1.5 mm 3 ). Twenty‐nine healthy subjects (14 female, 18–78 years) were enrolled, with 16 scanned at both 1.5 T and 3 T. Conventional maps were acquired using MOLLI and T 2 ‐prepared GRE sequences. Maps were analyzed by measuring mean global and regional T 1 and T 2 values, with spatial heterogeneity assessed using the coefficient of variation (CV). Bladder wall thickness (BWT) was measured from synthetic weighted images derived from MRF maps, compared to reference values from conventional T 2 ‐weighted MRI. Mean global MRF bladder wall measurements were 984 53 ms (T 1 ), 51.4 5.6 ms (T 2 ), and 4.5 1.6 mm (BWT) at 1.5 T and 1468 118 ms (T 1 ), 43.5 4.0 ms (T 2 ), and 4.3 1.6 mm (BWT) at 3 T. MRF T 1 values were significantly lower than MOLLI at 1.5 T (bias −151 ms) but not significantly different at 3 T. MRF T 2 values were significantly lower (by 7–8 ms) than T 2 ‐prepared GRE at both field strengths. MRF exhibited lower CV than MOLLI T 1 mapping at 1.5 T. BWT from synthetic images exhibited excellent agreement (bias .1 mm) with conventional T 2 ‐weighted images. Regionally, T 1 and T 2 tended to be higher in the dome and posterior wall. In an exploratory analysis, a positive association between age and T 2 was observed. In conclusion, 3D MRF of the bladder wall is feasible in healthy subjects, providing a baseline for translational studies to characterize pathological remodeling in LUTS.

Subjects

MeSH terms (MEDLINE)

Urinary BladderMagnetic Resonance ImagingImaging, Three-DimensionalHealthy VolunteersHumansFemaleAdultMiddle AgedAdolescentYoung AdultAgedMale

Author keywords

MR fingerprintingT1 mappingT2 mappingbladderdeep image priordeep learning

Authors and institutions

  • Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Urology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.

ORCID profiles: Shane A Wells, Giulia M Ippolito, Melis Ozkan, Wilson Sui, Anne P Cameron, Jesse I Hamilton

Funding

  • NHLBI NIH HHS
  • NIDDK NIH HHS
  • Siemens Healthineers
  • Society of Urodynamics, Female Pelvic Medicine and Urogenital Reconstruction Foundation
  • NIH
  • National Heart, Lung, and Blood Institute
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • National Institutes of Health

Cite

APA

Wells, S. A., Ippolito, G. M., Ozkan, M., Sui, W., Cameron, A. P., & Hamilton, J. I. (2026). 3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T. NMR in Biomedicine, 39(9). https://doi.org/10.1002/nbm.70366

Vancouver

Wells SA, Ippolito GM, Ozkan M, Sui W, Cameron AP, Hamilton JI. 3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T. NMR in Biomedicine. 2026;39(9). doi:10.1002/nbm.70366

BibTeX
@article{Wells2026,
  author = {Wells, Shane A and Ippolito, Giulia M and Ozkan, Melis and Sui, Wilson and Cameron, Anne P and Hamilton, Jesse I},
  title = {3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {9},
  doi = {10.1002/nbm.70366}
}
Start for free →