EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T

Shane A Wells iD, Giulia M Ippolito iD, Melis Ozkan iD, Wilson Sui iD, Anne P Cameron iD, Jesse I Hamilton iD

NMR in Biomedicine · 2026-09 · 39 (9)

DOI: 10.1002/nbm.70366 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 28.07.2026. Verfasst von Shane A Wells und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA. Hauptthemen laut MEDLINE: Urinary Bladder, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Healthy Volunteers. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIDDK NIH HHS, Siemens Healthineers.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Current diagnostic tests for lower urinary tract symptoms (LUTS) do not assess tissue‐level alterations in the bladder wall. This study assesses the feasibility of 3D magnetic resonance fingerprinting (MRF) for simultaneous T 1 , T 2 , and proton density (M 0 ) mapping of the bladder wall in healthy subjects at 1.5 T and 3 T. A 3D MRF acquisition was combined with a deep image prior reconstruction to achieve whole‐bladder T 1 , T 2 , and M 0 mapping in 11.8 min at an acquired voxel size of 1 × 1 × 3 mm 3 (interpolated to 0.5 × 0.5 × 1.5 mm 3 ). Twenty‐nine healthy subjects (14 female, 18–78 years) were enrolled, with 16 scanned at both 1.5 T and 3 T. Conventional maps were acquired using MOLLI and T 2 ‐prepared GRE sequences. Maps were analyzed by measuring mean global and regional T 1 and T 2 values, with spatial heterogeneity assessed using the coefficient of variation (CV). Bladder wall thickness (BWT) was measured from synthetic weighted images derived from MRF maps, compared to reference values from conventional T 2 ‐weighted MRI. Mean global MRF bladder wall measurements were 984 53 ms (T 1 ), 51.4 5.6 ms (T 2 ), and 4.5 1.6 mm (BWT) at 1.5 T and 1468 118 ms (T 1 ), 43.5 4.0 ms (T 2 ), and 4.3 1.6 mm (BWT) at 3 T. MRF T 1 values were significantly lower than MOLLI at 1.5 T (bias −151 ms) but not significantly different at 3 T. MRF T 2 values were significantly lower (by 7–8 ms) than T 2 ‐prepared GRE at both field strengths. MRF exhibited lower CV than MOLLI T 1 mapping at 1.5 T. BWT from synthetic images exhibited excellent agreement (bias .1 mm) with conventional T 2 ‐weighted images. Regionally, T 1 and T 2 tended to be higher in the dome and posterior wall. In an exploratory analysis, a positive association between age and T 2 was observed. In conclusion, 3D MRF of the bladder wall is feasible in healthy subjects, providing a baseline for translational studies to characterize pathological remodeling in LUTS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Urinary BladderMagnetic Resonance ImagingImaging, Three-DimensionalHealthy VolunteersHumansFemaleAdultMiddle AgedAdolescentYoung AdultAgedMale

Stichwörter der Autor:innen

MR fingerprintingT1 mappingT2 mappingbladderdeep image priordeep learning

Autor:innen und Institutionen

  • Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Urology, University of Michigan, Ann Arbor, Michigan, USA.
  • Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.

ORCID-Profile: Shane A Wells, Giulia M Ippolito, Melis Ozkan, Wilson Sui, Anne P Cameron, Jesse I Hamilton

Förderung

  • NHLBI NIH HHS
  • NIDDK NIH HHS
  • Siemens Healthineers
  • Society of Urodynamics, Female Pelvic Medicine and Urogenital Reconstruction Foundation
  • NIH
  • National Heart, Lung, and Blood Institute
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • National Institutes of Health

Zitieren

APA

Wells, S. A., Ippolito, G. M., Ozkan, M., Sui, W., Cameron, A. P., & Hamilton, J. I. (2026). 3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T. NMR in Biomedicine, 39(9). https://doi.org/10.1002/nbm.70366

Vancouver

Wells SA, Ippolito GM, Ozkan M, Sui W, Cameron AP, Hamilton JI. 3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T. NMR in Biomedicine. 2026;39(9). doi:10.1002/nbm.70366

BibTeX
@article{Wells2026,
  author = {Wells, Shane A and Ippolito, Giulia M and Ozkan, Melis and Sui, Wilson and Cameron, Anne P and Hamilton, Jesse I},
  title = {3D MR Fingerprinting for Quantitative Bladder Wall T 1 , T 2 , and M 0 Mapping in Healthy Subjects at 1.5 T and 3 T},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {9},
  doi = {10.1002/nbm.70366}
}
Kostenlos starten →