Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI
NMR in Biomedicine · 2026
DOI: 10.1002/nbm.70348 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift NMR in Biomedicine, 2026. Verfasst von Lærke S Gasbjerg und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Splanchnic Circulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: A.P. Møller Foundation, Rigshospitalet-Glostrup, Capital Region of Denmark.
Abstract (Originalsprache)
Splanchnic vessel blood flow assessment can describe physiology or pathophysiology and also has clinical relevance for patients with altered abdominal blood flow, vascular neuropathy, or atherosclerotic conditions. Reliable and practicable methods for this assessment are needed. We assessed the reproducibility of non‐invasive phase‐contrast MRI (PC‐MRI) for measuring splanchnic blood flow and its feasibility for detecting postprandial blood flow changes. We included measurements from two groups of healthy individuals (Group A: n = 10; C: n = 10) and a group of patients with type 2 diabetes (B: n = 10) from randomized, single‐blind, placebo‐controlled studies, and assessed blood flow with 2D PC sequences (3 Tesla Siemens Biograph MRI and 3 Tesla Philips Achieva). Blood flow was measured in the arteria mesenterica superior, truncus coeliacus, arteria hepatica (Group A only), and vena portae hepatis over multiple days, with repeated scans each day to assess variability and reproducibility. To confirm detection of postprandial changes, nine repeated measurements were acquired during ingestion of 75‐g oral glucose tolerance test compared to water ingestion. Reproducibility was assessed by coefficient of variation (CoV) and limits of agreement with the mean (LoAM) using an extended Bland–Altman analysis. Blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis demonstrated low intrasubject within session CoV (7%–22%) and intrasubject between session CoV (16%–26%). Blood flow in arteria hepatica had poorer CoV for both within sessions (12%) and between sessions (32%). Glucose ingestion induced a blood flow peak increase of 88% ± 52% in arteria mesenterica superior and 68% ± 36% in vena portae hepatis, both robustly detected, while no change was observed in the arteria hepatica or truncus coeliacus. In conclusion, PC‐MRI is a reproducible and feasible technique for measuring blood flow in arteria mesenterica superior, truncus coeliacus, and vena portae hepatis with the ability to detect postprandial changes. Trial Registration ClinicalTrials.gov identifier: NCT05391581, NCT06426823, NCT06774807
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
- Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital, Rigshospitalet, Glostrup, Denmark.
- Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark.
- Department of Clinical Physiology and Nuclear Medicine, Bispebjerg and Frederiksberg Hospital, University Hospital of Copenhagen, Copenhagen, Denmark.
ORCID-Profile: Sophie W Nielsen, Ulrik B Andersen, Bryan Haddock
Förderung
- A.P. Møller Foundation
- Rigshospitalet-Glostrup
- Capital Region of Denmark
- Department of Biomedical Sciences, University of Copenhagen
- Novo Nordisk Foundation
- European Foundation for the Study of Diabetes
- Hørslev Foundation
- King Christian the 10th Foundation
Zitieren
APA
Gasbjerg, L. S., Østergaard, F. H., Rasmussen, R. S., Langberg, L. S., Nielsen, S. W., Alstrup, L., Larsson, T. S. W., Andersen, U. B., Larsson, H. B. W., Asmar, A., Haddock, B., & Vestergaard, M. B. (2026). Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI. NMR in Biomedicine. https://doi.org/10.1002/nbm.70348
Vancouver
Gasbjerg LS, Østergaard FH, Rasmussen RS, Langberg LS, Nielsen SW, Alstrup L, et al. Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI. NMR in Biomedicine. 2026. doi:10.1002/nbm.70348
BibTeX
@article{Gasbjerg2026,
author = {Gasbjerg, Lærke S and Østergaard, Frederikke H and Rasmussen, Rasmus S and Langberg, Ludvig S and Nielsen, Sophie W and Alstrup, Lotte and Larsson, Tanne S W and Andersen, Ulrik B and Larsson, Henrik B W and Asmar, Ali and Haddock, Bryan and Vestergaard, Mark B},
title = {Reproducibility of Splanchnic Blood Flow Measured Using Phase‐Contrast MRI},
journal = {NMR in Biomedicine},
year = {2026},
doi = {10.1002/nbm.70348}
}
EUVIMED