Evaluation of 4D Flow MRI‐Derived Relative Residence Time as a Marker for Cirrhosis Associated Portal Vein Thrombosis
Journal of Magnetic Resonance Imaging · 2024
DOI: 10.1002/jmri.29357 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2024. Verfasst von Ryota Hyodo und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Japan. Hauptthemen laut MEDLINE: Portal Vein, Liver Cirrhosis, Venous Thrombosis, Magnetic Resonance Imaging. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: JSPS KAKENHI.
Abstract (Originalsprache)
Background
Portal vein thrombosis (PVT) is thought to arise from stagnant blood flow, yet conclusive evidence is lacking. Relative residence time (RRT) assessed using 4D Flow MRI may offer insight into portal flow stagnation.
Purpose
To explore the relationship between RRT values and the presence of PVT in cirrhotic participants. Study Type Prospective. Population Forty‐eight participants with liver cirrhosis (27 males, median age 67 years [IQR: 57–73]) and 20 healthy control participants (12 males, median age 45 years [IQR: 40–54]). Field Strength/Sequence 3 T/4D Flow MRI. Assessment Laboratory (liver and kidney function test results and platelet count) and clinical data (presence of tumors and other imaging findings), and portal hemodynamics derived from 4D Flow MRI (spatiotemporally averaged RRT [RRT‐mean], flow velocity, and flow rate) were analyzed. Statistical Tests We used multivariable logistic regression, adjusted by selected covariates through the Lasso method, to explore whether RRT‐mean is an independent risk factor for PVT. The area under the ROC curve (AUC) was also calculated to assess the model's discriminative ability. P < 0.05 indicated statistical significance.
Results
The liver cirrhosis group consisted of 16 participants with PVT and 32 without PVT. Higher RRT‐mean values (odds ratio [OR] 11.4 [95% CI: 2.19, 118]) and lower platelet count (OR 0.98 per 1000 μL [95% CI: 0.96, 0.99]) were independent risk factors for PVT. The incorporation of RRT‐mean (AUC, 0.77) alongside platelet count (AUC, 0.75) resulted in an AUC of 0.84. When including healthy control participants, RRT‐mean had an adjusted OR of 12.4 and the AUC of the combined model (RRT‐mean and platelet count) was 0.90. Data Conclusion Prolonged RRT values and low platelet count were significantly associated with the presence of PVT in cirrhotic participants. RRT values derived from 4D Flow MRI may have potential clinical relevance in the management of PVT. Evidence Level 2 Technical Efficacy Stage 2
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
- Center for Advanced Medicine and Clinical Research Department of Advanced Medicine, Nagoya University Hospital, Nagoya, Japan.
- Department of Radiological Technology, Nagoya University Hospital, Nagoya, Japan.
- Department of Transplantation Surgery, Nagoya University Hospital, Nagoya, Japan.
ORCID-Profile: Ryota Hyodo, Yasuo Takehara, Shinji Naganawa
Förderung
- JSPS KAKENHI
Zitieren
APA
Hyodo, R., Takehara, Y., Ishizu, Y., Nishida, K., Mizuno, T., Ichikawa, K., Horiguchi, R., Kurata, N., Ogura, Y., Yokoyama, S., Naganawa, S., Jin, N., & Ichiba, Y. (2024). Evaluation of 4D Flow MRI‐Derived Relative Residence Time as a Marker for Cirrhosis Associated Portal Vein Thrombosis. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29357
Vancouver
Hyodo R, Takehara Y, Ishizu Y, Nishida K, Mizuno T, Ichikawa K, et al. Evaluation of 4D Flow MRI‐Derived Relative Residence Time as a Marker for Cirrhosis Associated Portal Vein Thrombosis. Journal of Magnetic Resonance Imaging. 2024. doi:10.1002/jmri.29357
BibTeX
@article{Hyodo2024,
author = {Hyodo, Ryota and Takehara, Yasuo and Ishizu, Yoji and Nishida, Kazuki and Mizuno, Takashi and Ichikawa, Kazushige and Horiguchi, Ryota and Kurata, Nobuhiko and Ogura, Yasuhiro and Yokoyama, Shinya and Naganawa, Shinji and Jin, Ning and Ichiba, Yoshito},
title = {Evaluation of 4D Flow MRI‐Derived Relative Residence Time as a Marker for Cirrhosis Associated Portal Vein Thrombosis},
journal = {Journal of Magnetic Resonance Imaging},
year = {2024},
doi = {10.1002/jmri.29357}
}
EUVIMED