EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Residual Water Suppression in MRS Using HLSVD With Automatic Component Selection Strategy

Yi-Ru Lin, Zheng-De Hong, Shang-Yueh Tsai iD

NMR in Biomedicine · 2026-07 · 39 (7)

DOI: 10.1002/nbm.70325 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 31.05.2026. Verfasst von Yi-Ru Lin und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan. Hauptthemen laut MEDLINE: Water. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Residual water signals in magnetic resonance spectroscopy (MRS) can distort baselines and complicate metabolite quantification, particularly in regions with poor field homogeneity and in MRSI. The Hankel Lanczos singular value decomposition (HLSVD) method is widely used for Residual water removal, but its performance depends on the number of components selected. This study proposes an automatic approach that combines HLSVD with the residual water to metabolite variance ratio (RWVR) for component selection. The RWVR, defined as the variance of spectral fluctuations in the water region (4.2–5.2 ppm) normalized to the metabolite region (0.5–4.0 ppm). HLSVD was applied using component numbers between 10 and 32, and the configuration yielding the minimal RWVR was chosen as optimal. The method was evaluated on single voxel spectroscopy (SVS) data from four brain regions and on MRSI datasets acquired at 3 T. The Residual Water Index, defined as the variance ratio before and after RW removal, was used to assess suppression performance. Optimal component numbers were more frequently found in the range of 22–32, consistent with prior reports. With the identified component numbers, acceptable spectra across both SVS and MRSI can be produced. While multiple component numbers often yielded similar outcomes, some choices led to unacceptable spectra with baseline distortions. RWVR provided an effective indicator for avoiding such outcomes. Residual water index values were generally low, confirming effective suppression, though a small subset of cases exhibited irregular residual water lineshapes and higher RWVR. By evaluating multiple component numbers and choosing the configuration that minimizes RWVR, the proposed method avoids manual tuning and ensures acceptable suppression across both SVS and MRSI data. This approach offers a practical solution for large‐scale studies where consistent and reliable residual water removal is essential.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WaterMagnetic Resonance SpectroscopyHumansAlgorithmsBrainDimensionality ReductionMagnetic Resonance ImagingAutomation

Stichwörter der Autor:innen

HLSVDMRSresidual waterwater suppression

Substanzen

Water

Autor:innen und Institutionen

  • Department of Electronic and Computer Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan.
  • Graduate Institute of Applied Physics, National Chengchi University, Taipei, Taiwan.
  • Research Center for Mind, Brain and Learning, National Chengchi University, Taipei, Taiwan.

ORCID-Profile: Shang-Yueh Tsai

Förderung

  • National Science and Technology Council

Zitieren

APA

Lin, Y. R., Hong, Z. D., & Tsai, S. Y. (2026). Residual Water Suppression in MRS Using HLSVD With Automatic Component Selection Strategy. NMR in Biomedicine, 39(7). https://doi.org/10.1002/nbm.70325

Vancouver

Lin YR, Hong ZD, Tsai SY. Residual Water Suppression in MRS Using HLSVD With Automatic Component Selection Strategy. NMR in Biomedicine. 2026;39(7). doi:10.1002/nbm.70325

BibTeX
@article{Lin2026,
  author = {Lin, Yi-Ru and Hong, Zheng-De and Tsai, Shang-Yueh},
  title = {Residual Water Suppression in MRS Using HLSVD With Automatic Component Selection Strategy},
  journal = {NMR in Biomedicine},
  year = {2026},
  volume = {39},
  number = {7},
  doi = {10.1002/nbm.70325}
}
Kostenlos starten →