EUVIMEDEUVIMED entdecken
Open Access

Hybrid Multidelay PCASL Acquired With Time‐Encoded and Variable‐TR Schemes for the Assessment of Cerebral Perfusion in Moyamoya Disease

Osamu Togao iD, Makoto Obara, Koji Yamashita, Kazufumi Kikuchi, Tatsuhiro Wada, Chiaki Tokunaga, Ryoji Mikayama, Koichi Arimura, Ataru Nishimura, Shota Ishida, Lena Václavů, Matthias J P van Osch iD und 3 weitere

NMR in Biomedicine · 2025

DOI: 10.1002/nbm.70069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Osamu Togao und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan. Hauptthemen laut MEDLINE: Moyamoya Disease, Cerebrovascular Circulation, Magnetic Resonance Imaging. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multidelay arterial spin labeling (ASL) MRI requires balancing temporal information with signal‐to‐noise ratio (SNR). A hybrid scheme combines the high SNR of time‐encoded pseudo‐continuous ASL (PCASL) with the temporal flexibility of variable‐TR PCASL. The purpose of the present study was to assess the SNR and quantitative performance of the hybrid scheme by comparing it to time‐encoded and variable‐TR schemes for evaluating cerebral perfusion in patients with moyamoya disease. Twenty patients with moyamoya disease (8 men and 12 women, 27.6 ± 22.7 years) were scanned with 3 T MRI system. Variable‐TR PCASL with 12 delays (vTR12), time‐encoded PCASL with seven delays (TEnc7), and hybrid PCASL with 12 (4 × 3) delays (Hyb12) were obtained. Hyb12 and vTR12 were configured with nearly identical label duration (LD) and postlabeling delay (PLD) settings. For TEnc7, it was balanced so that the maximum LD + PLD time is the same. Time‐corrected SNR (SNR t ), cerebral blood flow (CBF), and arterial transit time (ATT) were measured in vascular territories within gray matter. The three parameters were compared using the Friedman's matched test, followed by the Dunn's multiple comparison test. Correlations were evaluated with Pearson's correlation, and agreement was assessed by Bland–Altman plot analysis and intraclass correlation coefficient (ICC). The SNR t of Hyb12 (4.67 ± 1.97) was significantly higher than that of vTR12 (3.27 ± 1.37, p < 0.0001) and TEnc7 (3.52 ± 1.32, p < 0.0001). The CBF of Hyb12 (49.9 ± 13.7 mL/100 g/min) was significantly lower than that of vTR12 (54.9 ± 15.4 mL/100 g/min, p < 0.0001) and TEnc7 (57.5 ± 15.9 mL/100 g/min, p < 0.0001). The ATT of Hyb12 (1240 ± 430 ms) was significantly shorter than that of vTR12 (1474 ± 419 ms, p < 0.0001) and TEnc7 (1402 ± 333 ms, p < 0.0001). CBF and ATT measurements from Hyb12 showed strong correlations and good agreement with the other two schemes. The hybrid scheme offers higher SNR t than both time‐encoded and variable‐TR schemes, which may improve the accuracy of cerebral perfusion assessment in patients with cerebral artery occlusive diseases, where delayed blood flow is a concern.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Moyamoya DiseaseCerebrovascular CirculationMagnetic Resonance ImagingHumansMaleFemaleAdultSpin LabelsYoung AdultSignal-To-Noise RatioTime FactorsAdolescentMiddle Aged

Stichwörter der Autor:innen

Moyamoya diseasearterial spin labelingcerebral perfusion

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
  • Philips Japan, Tokyo, Japan.
  • Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
  • Division of Radiology, Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
  • Department of Neurosurgery, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
  • Department of Radiological Technology, Faculty of Medical Sciences, Kyoto College of Medical Science, Kyoto, Japan.

ORCID-Profile: Osamu Togao, Matthias J P van Osch

Förderung

  • JSPS KAKENHI

Zitieren

APA

Togao, O., Obara, M., Yamashita, K., Kikuchi, K., Wada, T., Tokunaga, C., Mikayama, R., Arimura, K., Nishimura, A., Ishida, S., Václavů, L., van Osch, M. J. P., van de Ven, K., van Cauteren, M., & Ishigami, K. (2025). Hybrid Multidelay PCASL Acquired With Time‐Encoded and Variable‐TR Schemes for the Assessment of Cerebral Perfusion in Moyamoya Disease. NMR in Biomedicine. https://doi.org/10.1002/nbm.70069

Vancouver

Togao O, Obara M, Yamashita K, Kikuchi K, Wada T, Tokunaga C, et al. Hybrid Multidelay PCASL Acquired With Time‐Encoded and Variable‐TR Schemes for the Assessment of Cerebral Perfusion in Moyamoya Disease. NMR in Biomedicine. 2025. doi:10.1002/nbm.70069

BibTeX
@article{Togao2025,
  author = {Togao, Osamu and Obara, Makoto and Yamashita, Koji and Kikuchi, Kazufumi and Wada, Tatsuhiro and Tokunaga, Chiaki and Mikayama, Ryoji and Arimura, Koichi and Nishimura, Ataru and Ishida, Shota and Václavů, Lena and van Osch, Matthias J P and van de Ven, Kim and van Cauteren, Marc and Ishigami, Kousei},
  title = {Hybrid Multidelay PCASL Acquired With Time‐Encoded and Variable‐TR Schemes for the Assessment of Cerebral Perfusion in Moyamoya Disease},
  journal = {NMR in Biomedicine},
  year = {2025},
  doi = {10.1002/nbm.70069}
}
Kostenlos starten →