High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing
NMR in Biomedicine · 2025
DOI: 10.1002/nbm.70041 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Bobby A Runderkamp und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam Movement Sciences, Amsterdam, t…. Hauptthemen laut MEDLINE: Wrist, Magnetic Resonance Imaging, Imaging, Three-Dimensional, Data Compression. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
This study aimed to obtain high‐resolution 3D isotropic turbo spin‐echo (TSE) wrist MRI acquisitions at 7T, with and without fat suppression, facilitated by compressed‐sensing (CS) acceleration. In 16 healthy subjects, fat‐suppressed (FS) and nonfat‐suppressed (NFS) TSE wrist images were obtained. The protocol consisted of a SENSE‐accelerated scan, with an isotropic voxel size of 0.45 mm and acquisition time of 7 min (“SENSE45”), a 0.45‐mm, 4‐min CS‐accelerated scan (“CS45”), and a 0.35‐mm, 7‐min CS‐accelerated scan (“CS35”). For two subjects, additional 0.45‐mm, 4‐min SENSE‐accelerated scans were acquired (“High‐SENSE”). For the NFS scans, refocusing pulses were optimized to mitigate water‐fat chemical‐shift artifacts in the slab‐selection direction. Anatomical visibility of wrist structures and image quality were assessed qualitatively and through musculoskeletal radiologist grading. The use of nonselective hard refocusing pulses with optimized bandwidths and a center frequency in between water and fat enabled NFS imaging. The image quality of the faster CS45 scans was lower than for SENSE45, with statistically significantly different grading in 9/16 (FS) and 2/6 (NFS) grading parameters. Nonetheless, a similar scan time reduction could not be achieved using High‐SENSE. No distinct benefit of CS35 compared to SENSE45 was evident in either the FS or NFS scans. NFS CS35 exhibited enhanced bone sharpness compared to SENSE45 for some subjects, yet on a group level, the difference was not statistically significant. In conclusion, for maintained voxel size, CS presents the opportunity to achieve shorter scan times than possible with SENSE alone, but with reduced image quality. For maintained scan time, although higher resolution CS incidentally showed a promising increase in NFS bone sharpness compared to SENSE, it does not present an unequivocal advantage for 3D 7‐T TSE wrist MRI at this stage. Further optimization of the acquisition and reconstruction process is recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical Center, University of Amsterdam, Amsterdam Movement Sciences, Amsterdam, the Netherlands.
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Center, University of Amsterdam, Amsterdam Movement Sciences, Amsterdam, the Netherlands.
- Spinoza Centre for Neuroimaging, Royal Netherlands Academy for Arts and Sciences (KNAW), Amsterdam, the Netherlands.
- Computational and Cognitive Neuroscience and Neuroimaging, Netherlands Institute for Neuroscience, KNAW, Amsterdam, the Netherlands.
- Lund University Bioimaging Center, Lund University, Lund, Sweden.
- Philips Healthcare, Copenhagen, Denmark.
ORCID-Profile: Bobby A Runderkamp, Matthan W A Caan, Wietske van der Zwaag, Robert Hemke, Mario Maas, Mads Andersen, Gustav J Strijkers, Karin Markenroth Bloch, Aart J Nederveen
Zitieren
APA
Runderkamp, B. A., Caan, M. W. A., van der Zwaag, W., Hemke, R., Maas, M., Andersen, M., Strijkers, G. J., Markenroth Bloch, K., & Nederveen, A. J. (2025). High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing. NMR in Biomedicine. https://doi.org/10.1002/nbm.70041
Vancouver
Runderkamp BA, Caan MWA, van der Zwaag W, Hemke R, Maas M, Andersen M, et al. High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing. NMR in Biomedicine. 2025. doi:10.1002/nbm.70041
BibTeX
@article{Runderkamp2025,
author = {Runderkamp, Bobby A and Caan, Matthan W A and van der Zwaag, Wietske and Hemke, Robert and Maas, Mario and Andersen, Mads and Strijkers, Gustav J and Markenroth Bloch, Karin and Nederveen, Aart J},
title = {High‐Resolution 3D Turbo Spin‐Echo Wrist MRI at 7T Accelerated by Compressed Sensing},
journal = {NMR in Biomedicine},
year = {2025},
doi = {10.1002/nbm.70041}
}
EUVIMED