Spline Baseline Model Flexibility Independently Affects the Accuracy and Precision of In Vivo Proton Magnetic Resonance Spectral Fitting in a Metabolite‐Specific Manner Not Visually Predicted by Fit Residuals
NMR in Biomedicine · 2025
DOI: 10.1002/nbm.70010 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Kelley M Swanberg und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Columbia University Fu Foundation School of Engineering and Applied Science, New York, New York, USA. Hauptthemen laut MEDLINE: Proton Magnetic Resonance Spectroscopy, Metabolome. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: NIH HHS, NCATS NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
In vivo proton magnetic resonance spectroscopy ( 1 H‐MRS) data often exhibit baselines or low‐amplitude signal variations resulting from residual water, imperfectly suppressed lipids, low‐amplitude metabolites not considered for fitting, and other features not represented in a basis set. While multitudinous approaches exist to model these baselines in 1 H‐MR spectral analysis, many continue to lack systematic validation against varied and realistic ground‐truth standards. Here, we compare the accuracy (error mean) and precision (error standard deviation) of metabolite scaling estimates by linear combination modeling (LCM) spectral fitting accounting for spectral baselines via smoothed cubic splines at 50 different combinations of fixed knot interval and smoothing weight, either with or without additionally simulated Gaussian basis signals to separately model spectral macromolecules. Synthesized in‐vivo‐like metabolite brain spectra incorporating macromolecule signals measured using double‐inversion‐recovery‐prepared sLASER ( T E 20.1 ms; T R 2 s; T I 1 920 ms; T I 2 330 ms) at 3 T from single voxels in the frontal and occipital cortex of 10 healthy volunteers (five female; 23 ± 5 y.o.) provided both in vivo realism and a standard ground truth for error calculation. Optimal baseline flexibility differed both by definition of “optimum” as either accuracy or precision and by metabolite. Regardless of definition or metabolite, optimal models were not those yielding the smallest fit residuals. Optimized spline baseline definitions yielded high accuracies (lowest mean error −0.003 ± 2.1% for total N‐acetyl aspartate and highest mean error 10.1 ± 19.2% for glutamate + glutamine within fits including macromolecule bases) as well as comparable precision for most metabolites to fits achieved in LCModel; inclusion of simulated macromolecules in baseline models improved maximum fit precision but not accuracy. Taken together, these data illustrate that optimized spline baseline model flexibility exhibits metabolite‐specific relationships with 1 H‐MR spectral quantification accuracy or precision not readily predicted by visual inspection of associated fit residuals and not necessarily improved by adaptive relative to absolute constraints.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Columbia University Fu Foundation School of Engineering and Applied Science, New York, New York, USA.
- Department of Radiology, Columbia University College of Physicians and Surgeons, New York, New York, USA.
- High Field MR Center, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
ORCID-Profile: Kelley M Swanberg, Martin Gajdošík, Karl Landheer
Förderung
- NIH HHS
- NCATS NIH HHS
- National Institutes of Health
- National Center for Advancing Translational Sciences
Zitieren
APA
Swanberg, K. M., Gajdošík, M., Landheer, K., Treacy, M., & Juchem, C. (2025). Spline Baseline Model Flexibility Independently Affects the Accuracy and Precision of In Vivo Proton Magnetic Resonance Spectral Fitting in a Metabolite‐Specific Manner Not Visually Predicted by Fit Residuals. NMR in Biomedicine. https://doi.org/10.1002/nbm.70010
Vancouver
Swanberg KM, Gajdošík M, Landheer K, Treacy M, Juchem C. Spline Baseline Model Flexibility Independently Affects the Accuracy and Precision of In Vivo Proton Magnetic Resonance Spectral Fitting in a Metabolite‐Specific Manner Not Visually Predicted by Fit Residuals. NMR in Biomedicine. 2025. doi:10.1002/nbm.70010
BibTeX
@article{Swanberg2025,
author = {Swanberg, Kelley M and Gajdošík, Martin and Landheer, Karl and Treacy, Michael and Juchem, Christoph},
title = {Spline Baseline Model Flexibility Independently Affects the Accuracy and Precision of In Vivo Proton Magnetic Resonance Spectral Fitting in a Metabolite‐Specific Manner Not Visually Predicted by Fit Residuals},
journal = {NMR in Biomedicine},
year = {2025},
doi = {10.1002/nbm.70010}
}
EUVIMED