Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test–retest reliability and comparison to spin echo diffusion tensor imaging
NMR in Biomedicine · 2025
DOI: 10.1002/nbm.5279 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift NMR in Biomedicine, 2025. Verfasst von Adrian Alexander Marth und 5 weiteren Autor:innen. Beteiligte Einrichtung: Swiss Center for Musculoskeletal Imaging (SCMI), Balgrist Campus AG, Zurich, Switzerland. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Diffusion tensor imaging (DTI) provides insight into the skeletal muscle microstructure and can be acquired using a stimulated echo acquisition mode (STEAM)‐based approach to quantify time‐dependent tissue diffusion. This study examined diffusion metrics and signal‐to‐noise ratio (SNR) in the supraspinatus muscle obtained with a STEAM‐DTI sequence with different diffusion encoding times (Δ) and compared them to measures from a spin echo (SE) sequence. Ten healthy subjects (mean age 31.5 ± 4.7 years; five females) underwent 3‐Tesla STEAM and SE‐DTI of the shoulder in three sessions. STEAM was acquired with Δ of 100/200/400/600 ms. The diffusion encoding time in SE scans was 19 ms ( b = 500 s/mm 2 ). Region of interest‐based measurement of fractional anisotropy (FA), mean diffusivity (MD), and SNR was performed. Intraclass correlation coefficients (ICCs) were computed to assess test–retest reliability. ANOVA with post‐hoc pairwise tests was used to compare measures between different Δ of STEAM as well as STEAM and SE, respectively. FA was significantly higher (FA STEAM : 0.38–0.46 vs. FA SE : 0.26) and MD significantly lower (MD STEAM : 1.20–1.33 vs. MD SE : 1.62 × 10 −3 mm 2 /s) in STEAM compared to SE ( p < 0.001, respectively). SNR was significantly higher for SE (72.3 ± 8.7) than for STEAM ( p < 0.001). ICCs were excellent for FA in STEAM (≥0.911) and SE (0.960). For MD, ICCs were good for STEAM 100ms–600ms (≥0.759) and SE (0.752). STEAM and SE exhibited excellent reliability for FA and good reliability for MD in the supraspinatus muscle. SNR was significantly higher in SE compared to STEAM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Swiss Center for Musculoskeletal Imaging (SCMI), Balgrist Campus AG, Zurich, Switzerland.
- Department of Radiology, Balgrist University Hospital, Zurich, Switzerland.
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Zurich, Switzerland.
- Siemens Healthineers AG, Erlangen, Germany.
- Medical Faculty, University of Zurich (UZH), Zurich, Switzerland.
ORCID-Profile: Adrian Alexander Marth
Zitieren
APA
Marth, A. A., Sommer, S., Feiweier, T., Sutter, R., Nanz, D., & von Deuster, C. (2025). Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test–retest reliability and comparison to spin echo diffusion tensor imaging. NMR in Biomedicine. https://doi.org/10.1002/nbm.5279
Vancouver
Marth AA, Sommer S, Feiweier T, Sutter R, Nanz D, von Deuster C. Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test–retest reliability and comparison to spin echo diffusion tensor imaging. NMR in Biomedicine. 2025. doi:10.1002/nbm.5279
BibTeX
@article{Marth2025,
author = {Marth, Adrian Alexander and Sommer, Stefan and Feiweier, Thorsten and Sutter, Reto and Nanz, Daniel and von Deuster, Constantin},
title = {Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test–retest reliability and comparison to spin echo diffusion tensor imaging},
journal = {NMR in Biomedicine},
year = {2025},
doi = {10.1002/nbm.5279}
}
EUVIMED