EUVIMEDEUVIMED entdecken
Crossref

Visualization of Human Hand Tendon Mechanical Anisotropy in 3-D Using High- Frequency Dual-Direction Shear Wave Imaging

Guo-Xuan Xu, Pei-Yu Chen, Chih-Chung Huang

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · 2023

DOI: 10.1109/tuffc.2023.3312273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2023. Verfasst von Guo-Xuan Xu und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Tendons, Elasticity Imaging Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 66 Literaturangaben. Gefördert von: National Health Research Institutes.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-resolution ultrasound shear wave elastography has been used to determine the mechanical properties of hand tendons. However, because of fiber orientation, tendons have anisotropic properties; this results in differences in shear wave velocity (SWV) between ultrasound scanning cross sections. Rotating transducers can be used to achieve full-angle scanning. However, this technique is inconvenient to implement in clinical settings. Therefore, in this study, high-frequency ultrasound (HFUS) dual-direction shear wave imaging (DDSWI) based on two external vibrators was used to create both transverse and longitudinal shear waves in the human flexor carpi radialis tendon. SWV maps from two directions were obtained using 40-MHz ultrafast imaging at the same scanning cross section. The anisotropic map was calculated pixel by pixel, and 3-D information was obtained using mechanical scanning. A standard phantom experiment was then conducted to verify the performance of the proposed HFUS DDSWI technique. Human studies were also conducted where volunteers assumed three hand postures: relaxed (Rel), full fist (FF), and tabletop (TT). The experimental results indicated that both the transverse and longitudinal SWVs increased due to tendon flexion. The transverse SWV surpassed the longitudinal SWV in all cases. The average anisotropic ratios for the Rel, FF, and TT hand postures were 1.78, 2.01, and 2.21, respectively. Both the transverse and the longitudinal SWVs were higher at the central region of the tendon than at the surrounding region. In conclusion, the proposed HFUS DDSWI technique is a high-resolution imaging technique capable of characterizing the anisotropic properties of tendons in clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TendonsElasticity Imaging TechniquesHumansAnisotropyUltrasonographyPhantoms, Imaging

Förderung

  • National Health Research Institutes

Zitieren

APA

Xu, G. X., Chen, P. Y., & Huang, C. C. (2023). Visualization of Human Hand Tendon Mechanical Anisotropy in 3-D Using High- Frequency Dual-Direction Shear Wave Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. https://doi.org/10.1109/tuffc.2023.3312273

Vancouver

Xu GX, Chen PY, Huang CC. Visualization of Human Hand Tendon Mechanical Anisotropy in 3-D Using High- Frequency Dual-Direction Shear Wave Imaging. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 2023. doi:10.1109/tuffc.2023.3312273

BibTeX
@article{Xu2023,
  author = {Xu, Guo-Xuan and Chen, Pei-Yu and Huang, Chih-Chung},
  title = {Visualization of Human Hand Tendon Mechanical Anisotropy in 3-D Using High- Frequency Dual-Direction Shear Wave Imaging},
  journal = {IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control},
  year = {2023},
  doi = {10.1109/tuffc.2023.3312273}
}
Kostenlos starten →