Model‐based reconstructions for intravoxel incoherent motion and diffusion tensor imaging parameter map estimations
NMR in Biomedicine · 2023
DOI: 10.1002/nbm.4927 ↗Kurz gefasst
Fachartikel in der Zeitschrift NMR in Biomedicine, 2023. Verfasst von Susanne S Rauh und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam Movement Sciences, University of Amsterdam, The Netherlands. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Diffusion Magnetic Resonance Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Österreichischen Akademie der Wissenschaften.
Abstract (Originalsprache)
Intravoxel incoherent motion (IVIM) imaging and diffusion tensor imaging (DTI) facilitate noninvasive quantification of tissue perfusion and diffusion. Both are promising biomarkers in various diseases and a combined acquisition is therefore desirable. This comes with challenges, including noisy parameter maps and long scan times, especially for the perfusion fraction f and pseudo‐diffusion coefficient D*. A model‐based reconstruction has the potential to overcome these challenges. As a first step, our goal was to develop a model‐based reconstruction framework for IVIM and combined IVIM‐DTI parameter estimation. The IVIM and IVIM‐DTI models were implemented in the PyQMRI model‐based reconstruction framework and validated with simulations and in vivo data. Commonly used voxel‐wise nonlinear least‐squares fitting was used as the reference. Simulations with the IVIM and IVIM‐DTI models were performed with 100 noise realizations to assess accuracy and precision. Diffusion‐weighted data were acquired for IVIM reconstruction in the liver (n = 5), as well as for IVIM‐DTI in the kidneys (n = 5) and lower‐leg muscles (n = 6) of healthy volunteers. The median and interquartile range (IQR) values of the IVIM and IVIM‐DTI parameters were compared to assess bias and precision. With model‐based reconstruction, the parameter maps exhibited less noise, which was most pronounced in the f and D* maps, both in the simulations and in vivo. The bias values in the simulations were comparable between model‐based reconstruction and the reference method. The IQR was lower with model‐based reconstruction compared with the reference for all parameters. In conclusion, model‐based reconstruction is feasible for IVIM and IVIM‐DTI and improves the precision of the parameter estimates, particularly for f and D* maps.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering and Physics, Amsterdam UMC, Amsterdam Movement Sciences, University of Amsterdam, The Netherlands.
- Institute of Medical Engineering, Graz University of Technology, Graz, Austria.
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, Amsterdam Movement Sciences, University of Amsterdam, The Netherlands.
ORCID-Profile: Susanne S Rauh, Melissa T Hooijmans
Förderung
- Österreichischen Akademie der Wissenschaften
Zitieren
APA
Rauh, S. S., Maier, O., Gurney-Champion, O. J., Hooijmans, M. T., Stollberger, R., Nederveen, A. J., & Strijkers, G. J. (2023). Model‐based reconstructions for intravoxel incoherent motion and diffusion tensor imaging parameter map estimations. NMR in Biomedicine. https://doi.org/10.1002/nbm.4927
Vancouver
Rauh SS, Maier O, Gurney-Champion OJ, Hooijmans MT, Stollberger R, Nederveen AJ, et al. Model‐based reconstructions for intravoxel incoherent motion and diffusion tensor imaging parameter map estimations. NMR in Biomedicine. 2023. doi:10.1002/nbm.4927
BibTeX
@article{Rauh2023,
author = {Rauh, Susanne S and Maier, Oliver and Gurney-Champion, Oliver J and Hooijmans, Melissa T and Stollberger, Rudolf and Nederveen, Aart J and Strijkers, Gustav J},
title = {Model‐based reconstructions for intravoxel incoherent motion and diffusion tensor imaging parameter map estimations},
journal = {NMR in Biomedicine},
year = {2023},
doi = {10.1002/nbm.4927}
}
EUVIMED