Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients
Magnetic Resonance in Medicine · 2024
DOI: 10.1002/mrm.29924 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Danielle Kara und 4 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA. Hauptthemen laut MEDLINE: Diffusion Tensor Imaging, Brain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NHLBI NIH HHS, NIH HHS.
Abstract (Originalsprache)
Purpose
To demonstrate the feasibility of motion compensating diffusion gradient schemes in the acquisition of quality diffusion tensor images (DTI) of the brain during continuous gross head motion.
Methods
Five healthy subjects were scanned using a clinical 3 T MRI with and without continuous head motion. For one volunteer, DTI data was acquired using standard (M0) diffusion‐weighted (DW) gradients, and first (M1) and second (M2) order gradient schemes that were previously developed for use in cardiac DTI. In four additional volunteers, DTI data was acquired with M0 and M2 gradients. DTI parameters were calculated and compared with established retrospective motion corrections.
Results
In the absence of motion, DTI parameters calculated from M0, M1, and M2 data were consistent. In the presence of motion, up to 44% of DW images acquired with M0 gradients were corrupted by signal dropout, compared to 0% of the M2 images. In voxelwise comparisons, DTI parameters calculated using motion‐M0 data were elevated compared to reference data. Retrospective corrections for extreme motion applied to motion‐M0 data did not improve consistency with reference data in cases where motion corrupted >15% of DW images. In contrast, DTI parameters calculated with motion‐M2 data were consistent with reference data.
Conclusion
This proof‐of‐principle study demonstrates that motion compensating diffusion gradients can mitigate artifacts because of continuous motion in DTI of the brain and offers promise for improved DTI accessibility. Further study will be necessary to determine the robustness of the approach in patient populations with high susceptibility to head motion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiovascular Innovation Research Center, Heart, Vascular, and Thoracic Institute, Cleveland Clinic, Cleveland, Ohio, USA.
- Imaging Sciences, Imaging Institute, Cleveland Clinic, Cleveland, Ohio, USA.
- Biomedical Engineering, Lerner Research Institute, Cleveland Clinic and Case Western Reserve University, Cleveland, Ohio, USA.
ORCID-Profile: Danielle Kara, Christopher T Nguyen
Förderung
- NIBIB NIH HHS
- NHLBI NIH HHS
- NIH HHS
- National Institutes of Health
Zitieren
APA
Kara, D., Koenig, K., Lowe, M., Nguyen, C. T., & Sakaie, K. (2024). Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.29924
Vancouver
Kara D, Koenig K, Lowe M, Nguyen CT, Sakaie K. Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.29924
BibTeX
@article{Kara2024,
author = {Kara, Danielle and Koenig, Katherine and Lowe, Mark and Nguyen, Christopher T and Sakaie, Ken},
title = {Facilitating diffusion tensor imaging of the brain during continuous gross head motion with first and second order motion compensating diffusion gradients},
journal = {Magnetic Resonance in Medicine},
year = {2024},
doi = {10.1002/mrm.29924}
}
EUVIMED