EUVIMEDEUVIMED entdecken
Open Access

4D Golden‐Angle Radial MRI at Subsecond Temporal Resolution

Li Feng iD

NMR in Biomedicine · 2023-02 · 36 (2)

DOI: 10.1002/nbm.4844 ↗

Kurz gefasst

Fachartikel in der Zeitschrift NMR in Biomedicine, online erschienen am 25.11.2022. Verfasst von Li Feng. Beteiligte Einrichtung: Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA. Hauptthemen laut MEDLINE: Contrast Media, Respiration. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intraframe motion blurring, as a major challenge in free‐breathing dynamic MRI, can be reduced if high temporal resolution can be achieved. To address this challenge, this work proposes a highly accelerated 4D (3D + time) dynamic MRI framework with subsecond temporal resolution that does not require explicit motion compensation. The method combines standard stack‐of‐stars golden‐angle radial sampling and tailored GRASP‐Pro (Golden‐angle RAdial Sparse Parallel imaging with imProved performance) reconstruction. Specifically, 4D dynamic MRI acquisition is performed continuously without motion gating or sorting. The k‐space centers in stack‐of‐stars radial data are organized to guide estimation of a temporal basis, with which GRASP‐Pro reconstruction is employed to enforce joint low‐rank subspace and sparsity constraints. This new basis estimation strategy is the new feature proposed for subspace‐based reconstruction in this work to achieve high temporal resolution (e.g., subsecond/3D volume). It does not require sequence modification to acquire additional navigation data, it is compatible with commercially available stack‐of‐stars sequences, and it does not need an intermediate reconstruction step. The proposed 4D dynamic MRI approach was tested in abdominal motion phantom, free‐breathing abdominal MRI, and dynamic contrast‐enhanced MRI (DCE‐MRI). Our results have shown that GRASP‐Pro reconstruction with the new basis estimation strategy enables highly‐accelerated 4D dynamic imaging at subsecond temporal resolution (with five spokes or less for each dynamic frame per image slice) for both free‐breathing non‐DCE‐MRI and DCE‐MRI. In the abdominal phantom, better image quality with lower root mean square error and higher structural similarity index was achieved using GRASP‐Pro compared with standard GRASP. With the ability to acquire each 3D image in less than 1 s, intraframe respiratory blurring can be intrinsically reduced for body applications with our approach, which eliminates the need for explicit motion detection and motion compensation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaRespirationMagnetic Resonance ImagingImaging, Three-DimensionalAbdomen

Stichwörter der Autor:innen

DCE-MRIGRASPGRASP-Prodynamic MRImotion correctionradial samplingstack-of-starssubspace

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York, USA.

ORCID-Profile: Li Feng

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Feng, L. (2023). 4D Golden‐Angle Radial MRI at Subsecond Temporal Resolution. NMR in Biomedicine, 36(2). https://doi.org/10.1002/nbm.4844

Vancouver

Feng L. 4D Golden‐Angle Radial MRI at Subsecond Temporal Resolution. NMR in Biomedicine. 2023;36(2). doi:10.1002/nbm.4844

BibTeX
@article{Feng2023,
  author = {Feng, Li},
  title = {4D Golden‐Angle Radial MRI at Subsecond Temporal Resolution},
  journal = {NMR in Biomedicine},
  year = {2023},
  volume = {36},
  number = {2},
  doi = {10.1002/nbm.4844}
}
Kostenlos starten →