EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Linear projection‐based chemical exchange saturation transfer parameter estimation

Felix Glang iD, Moritz S Fabian, Alexander German iD, Katrin M Khakzar, Angelika Mennecke iD, Andrzej Liebert iD, Kai Herz iD, Patrick Liebig iD, Burkhard S Kasper, Manuel Schmidt, Enrique Zuazua iD, Armin M Nagel iD and 4 more

NMR in Biomedicine · 2023-06 · 36 (6)

DOI: 10.1002/nbm.4697 ↗

At a glance

Journal article in NMR in Biomedicine, published online on 2022-02-28. Written by Felix Glang and 15 co-authors. Institution: Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany. Major MEDLINE topics: Multiparametric Magnetic Resonance Imaging, Brain. Cited 18 times so far (Crossref); 52 references. The full text is freely available (open access, CC BY 4.0). Funded by: Max-Planck-Gesellschaft.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Isolated evaluation of multiparametric in vivo chemical exchange saturation transfer (CEST) MRI often requires complex computational processing for both correction of B 0 and B 1 inhomogeneity and contrast generation. For that, sufficiently densely sampled Z‐spectra need to be acquired. The list of acquired frequency offsets largely determines the total CEST acquisition time, while potentially representing redundant information. In this work, a linear projection‐based multiparametric CEST evaluation method is introduced that offers fast B 0 and B 1 inhomogeneity correction, contrast generation and feature selection for CEST data, enabling reduction of the overall measurement time. To that end, CEST data acquired at 7 T in six healthy subjects and in one brain tumor patient were conventionally evaluated by interpolation‐based inhomogeneity correction and Lorentzian curve fitting. Linear regression was used to obtain coefficient vectors that directly map uncorrected data to corrected Lorentzian target parameters. L1‐regularization was applied to find subsets of the originally acquired CEST measurements that still allow for such a linear projection mapping. The linear projection method allows fast and interpretable mapping from acquired raw data to contrast parameters of interest, generalizing from healthy subject training data to unseen healthy test data and to the tumor patient dataset. The L1‐regularization method shows that a fraction of the acquired CEST measurements is sufficient to preserve tissue contrasts, offering up to a 2.8‐fold reduction of scan time. Similar observations as for the 7‐T data can be made for data from a clinical 3‐T scanner. Being a fast and interpretable computation step, the proposed method is complementary to neural networks that have recently been employed for similar purposes. The scan time acceleration offered by the L1‐regularization (“CEST‐LASSO”) constitutes a step towards better applicability of multiparametric CEST protocols in a clinical context.

Subjects

MeSH terms (MEDLINE)

Multiparametric Magnetic Resonance ImagingBrainHumansNeural Networks, ComputerBrain Neoplasms

Author keywords

APTCESTLASSONOEfeature selectionlinear projection

Authors and institutions

  • Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Department of Neuroradiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany.
  • Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany.
  • Department of Biomedical Magnetic Resonance, Eberhard Karls University Tübingen, Tübingen, Germany.
  • Siemens Healthcare GmbH, Erlangen, Germany.
  • Department of Neurology, University Clinic of Friedrich Alexander University Erlangen-Nürnberg, Erlangen, Germany.

ORCID profiles: Felix Glang, Alexander German, Angelika Mennecke, Andrzej Liebert, Kai Herz, Patrick Liebig, Enrique Zuazua, Armin M Nagel, Klaus Scheffler, Moritz Zaiss

Funding

  • Max-Planck-Gesellschaft

Cite

APA

Glang, F., Fabian, M. S., German, A., Khakzar, K. M., Mennecke, A., Liebert, A., Herz, K., Liebig, P., Kasper, B. S., Schmidt, M., Zuazua, E., Nagel, A. M., Laun, F. B., Dörfler, A., Scheffler, K., & Zaiss, M. (2023). Linear projection‐based chemical exchange saturation transfer parameter estimation. NMR in Biomedicine, 36(6). https://doi.org/10.1002/nbm.4697

Vancouver

Glang F, Fabian MS, German A, Khakzar KM, Mennecke A, Liebert A, et al. Linear projection‐based chemical exchange saturation transfer parameter estimation. NMR in Biomedicine. 2023;36(6). doi:10.1002/nbm.4697

BibTeX
@article{Glang2023,
  author = {Glang, Felix and Fabian, Moritz S and German, Alexander and Khakzar, Katrin M and Mennecke, Angelika and Liebert, Andrzej and Herz, Kai and Liebig, Patrick and Kasper, Burkhard S and Schmidt, Manuel and Zuazua, Enrique and Nagel, Armin M and Laun, Frederik B and Dörfler, Arnd and Scheffler, Klaus and Zaiss, Moritz},
  title = {Linear projection‐based chemical exchange saturation transfer parameter estimation},
  journal = {NMR in Biomedicine},
  year = {2023},
  volume = {36},
  number = {6},
  doi = {10.1002/nbm.4697}
}
Start for free →