Ultrasonographic Identification of Pacinian Corpuscles in the Hand: A Pilot Study of Technique and Reliability
Muscle & Nerve · 2025
DOI: 10.1002/mus.28423 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscle & Nerve, 2025. Verfasst von Nicholas J Miller und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada. Hauptthemen laut MEDLINE: Pacinian Corpuscles, Hand. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction/Aims Pacinian corpuscles are end organs of the sensory nervous system. The size and superficial location of Pacinian corpuscles allows them to be visualized with high‐resolution ultrasound. This pilot study sought to assess the reliability of Pacinian corpuscle counting in the hand using ultrasound.
Methods
Two healthy participants underwent ultrasound evaluation by three ultrasonographers using a scanning protocol developed for this study. The ultrasound protocol used anatomic landmarks to identify and trace digital nerves in the palms and the adjacent Pacinian corpuscles. The ultrasonographers used morphologic features to identify and count Pacinian corpuscles at two sites in each hand for each participant using a 10–22 MHz linear‐array transducer. The procedure was repeated at 2 time points. Inter‐rater and intrarater reliabilities were determined using intraclass correlation coefficients (ICCs).
Results
Pacinian corpuscles were identified in the second–third and fourth–fifth intermetacarpal spaces. The ultrasound appearance of Pacinian corpuscles is of a hypoechoic, rounded structure without a hyperechoic rim. A clustered appearance and septate internal structure are distinct features of Pacinian corpuscles, but these features are not always present. The mean number at each site was between 10.71 and 11.71. Inter‐rater and intrarater reliability both resulted in ICC values over 0.8, indicating “good” inter‐rater and intrarater reliabilities.
Discussion
Pacinian corpuscles can be reliably counted in the hand using high‐resolution ultrasound. The reliability data from this pilot study may facilitate further ultrasound studies of Pacinian corpuscles, which may be decreased in number or undergo other changes in polyneuropathies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada.
- Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota, USA.
- Department of Neurology, Mayo Clinic, Rochester, Minnesota, USA.
- Department of Neurology, Wake Forest School of Medicine, Winston-Salem, North Carolina, USA.
ORCID-Profile: James B Meiling, Francis O Walker
Zitieren
APA
Miller, N. J., Meiling, J. B., Walker, F. O., & Cartwright, M. S. (2025). Ultrasonographic Identification of Pacinian Corpuscles in the Hand: A Pilot Study of Technique and Reliability. Muscle & Nerve. https://doi.org/10.1002/mus.28423
Vancouver
Miller NJ, Meiling JB, Walker FO, Cartwright MS. Ultrasonographic Identification of Pacinian Corpuscles in the Hand: A Pilot Study of Technique and Reliability. Muscle & Nerve. 2025. doi:10.1002/mus.28423
BibTeX
@article{Miller2025,
author = {Miller, Nicholas J and Meiling, James B and Walker, Francis O and Cartwright, Michael S},
title = {Ultrasonographic Identification of Pacinian Corpuscles in the Hand: A Pilot Study of Technique and Reliability},
journal = {Muscle & Nerve},
year = {2025},
doi = {10.1002/mus.28423}
}
EUVIMED