Pixel‐Wise Uncertainty Quantification of Accelerated MRI Reconstruction
Magnetic Resonance in Medicine · 2026-12 · 96 (6) · 2937-2949
DOI: 10.1002/mrm.70526 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 26.07.2026. Verfasst von Ilias I Giannakopoulos und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Purpose
The goal of this work is to introduce an automated method to assess the quality of under‐sampled MRI reconstructions. Theory and Methods We propose a general framework for pixel‐wise uncertainty quantification in accelerated MRI reconstructions, enabling automatic identification of unreliable regions without using ground‐truth fully‐sampled reference images. Our method integrates conformal quantile regression with learning‐based image reconstruction methods to estimate statistically rigorous pixel‐wise uncertainty intervals. We trained and evaluated our model on Cartesian undersampled brain and knee data obtained from the fastMRI dataset using acceleration factors ranging from 2 to 10. An end‐to‐end Variational Network was used for image reconstruction.
Results
Quantitative experiments demonstrate strong agreement between predicted uncertainty maps and true reconstruction error. Using our method, the corresponding Pearson correlation coefficient was higher than 90% at acceleration levels at and above four‐fold; whereas it dropped to less than 70% when the uncertainty was computed using a simpler heuristic notion (magnitude of the residual). Qualitative examples further show the uncertainty maps based on quantile regression capture the magnitude and spatial distribution of reconstruction errors across acceleration factors, with regions of elevated uncertainty aligning with pathologies and artifacts.
Conclusion
The proposed framework enables evaluation of reconstruction quality without access to fully‐sampled ground‐truth reference images. It represents a step toward adaptive MRI acquisition protocols that may be able to dynamically balance scan time and diagnostic reliability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
- Courant Institute School of Mathematics, Computing, and Data Science, New York University, New York, New York, USA.
- The Center for Advanced Imaging Innovation and Research (CAI2R), Department of Radiology, New York University Grossman School of Medicine, New York, New York, USA.
ORCID-Profile: Ilias I Giannakopoulos, Lokesh B Gautham Muthukumar, Yvonne W Lui, Riccardo Lattanzi
Förderung
- NIH HHS
- National Institutes of Health
Zitieren
APA
Giannakopoulos, I. I., Gautham Muthukumar, L. B., Lui, Y. W., & Lattanzi, R. (2026). Pixel‐Wise Uncertainty Quantification of Accelerated MRI Reconstruction. Magnetic Resonance in Medicine, 96(6), 2937-2949. https://doi.org/10.1002/mrm.70526
Vancouver
Giannakopoulos II, Gautham Muthukumar LB, Lui YW, Lattanzi R. Pixel‐Wise Uncertainty Quantification of Accelerated MRI Reconstruction. Magnetic Resonance in Medicine. 2026;96(6):2937-2949. doi:10.1002/mrm.70526
BibTeX
@article{Giannakopoulos2026,
author = {Giannakopoulos, Ilias I and Gautham Muthukumar, Lokesh B and Lui, Yvonne W and Lattanzi, Riccardo},
title = {Pixel‐Wise Uncertainty Quantification of Accelerated MRI Reconstruction},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {6},
pages = {2937--2949},
doi = {10.1002/mrm.70526}
}