A Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70496 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Julius Glaser und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Brain. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Friedrich-Alexander-Universität Erlangen-Nürnberg, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
Purpose
To present a novel, nonlinear subspace modeling and joint k–q‐space reconstruction technique for high‐resolution, multi‐band, multi‐shell diffusion‐weighted imaging (DWI).
Methods
High b ‐value (> 1000 s/mm 2 ), high resolution DWI has the drawback of generally low signal‐to‐noise ratios (SNRs). We present an approach that leverages a denoising autoencoder (DAE) to learn a latent subspace from biophysically simulated diffusion‐weighted signals. The decoder of this network is then used in the forward operator of the image reconstruction process. The decoded latent images are scaled by the image, phase is added and processed as regular DWI images with the forward operator for multi‐shot, multicoil, multi‐slice, k–q‐undersampled acquisition schemes. The performance is investigated with a multi‐shell, multi‐direction imaging brain scan and compared to the results of the multiplexed sensitivity‐encoding (MUSE) reconstruction and locally low‐rank (LLR) regularized reconstruction. The results are further validated by a bias and precision analysis of reconstructed fiber directions.
Results
Comparing the reconstructed data using the proposed method shows improved noise suppression compared to MUSE and more details than LLR‐reconstructed images. Specifically, in the higher b ‐value domain, the reconstruction results show improved detectability of small structures. This bias and precision analysis showed minimal bias introduction, but higher precision with the proposed method.
Conclusion
Our method combines deep learning, latent signal modeling, joint k–q‐space reconstruction, and biophysical simulation for diffusion data and shows strong noise suppression and a high degree of detail in reconstructed diffusion‐weighted images.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
- Michigan Institute for Imaging Technology and Translation (MIITT), Radiology, University of Michigan, Ann Arbor, Michigan, USA.
- Department Artificial Intelligence in Biomedical Engineering (AIBE), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
ORCID-Profile: Julius Glaser, Zhengguo Tan, Annika Hofmann, Frederik Bernd Laun, Florian Knoll
Förderung
- Friedrich-Alexander-Universität Erlangen-Nürnberg
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Glaser, J., Tan, Z., Hofmann, A., Laun, F. B., & Knoll, F. (2026). A Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70496
Vancouver
Glaser J, Tan Z, Hofmann A, Laun FB, Knoll F. A Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70496
BibTeX
@article{Glaser2026,
author = {Glaser, Julius and Tan, Zhengguo and Hofmann, Annika and Laun, Frederik Bernd and Knoll, Florian},
title = {A Deep Nonlinear Subspace Modeling and Reconstruction for Diffusion‐Weighted Imaging Using Denoising Auto‐Encoder},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70496}
}
EUVIMED