Journal article in Magnetic Resonance in Medicine, 2026. Written by Xin Guo and 12 co-authors. Institution: Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China. Major MEDLINE topics: Magnetic Resonance Angiography, Hand, Veins, Arteries. Cited 1 times so far (Crossref); 26 references. Funded by: Shanghai Science and Technology Commission "Explorer Project", National Natural Science Foundation of China.
Abstract (original language)
Purpose
To develop a non‐contrast‐enhanced MR angiography method for imaging slow‐flow hand vessels that enables flow velocity measurement and artery–vein separation.
Methods
A slow‐flow‐sensitive artery–vein‐separated velocity mapping phase‐contrast MR angiography (SAM PC‐MRA) technique was developed, employing multiple velocity encodings (VENCs). Ultra‐low VENC acquisitions enhanced visualization of slow‐flow vasculature, while high‐VENC acquisitions enabled velocity mapping and artery–vein separation based on flow direction. MRA was performed on a 5 T MR system in 20 healthy volunteers and one patient with vasculitis. Vessel delineation scores, signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and vascular morphology metrics were compared with conventional 3D PC‐MRA at VENCs of 5 and 10 cm/s. Flow velocity measurements were validated against 2D PC.
Results
SAM‐PC demonstrated superior visualization of small vessels with reliable artery–vein separation and flow velocity mapping. Across healthy volunteers, vessel delineation scores were significantly higher with SAM‐PC compared with 3D PC at VENCs of 5 and 10 cm/s (3.9 vs. 3.3 vs. 2.9, p < 0.001), with average SNR increasing by 37.6% and 74.8% and CNR by 69.8% and 131.2%. More vessels were detected (16 571 vs. 10 132 vs. 7856, p < 0.001), and flow velocity showed no significant difference from 2D PC ( p = 0.389, r = 0.835). SAM‐PC in the vasculitis patient demonstrated an absence of blood flow in the necrotic fingers.
Conclusions
SAM PC‐MRA enables high‐resolution visualization of slow‐flow hand vessels with accurate time‐averaged flow quantification and artery–vein separation.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China.
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, China.
- Shanghai Institute of Medical Imaging, Shanghai, China.
- Shanghai United Imaging Healthcare Co. Ltd., Shanghai, China.
ORCID profiles: Xin Guo, Bingyi Wang, Hao Li
Funding
- Shanghai Science and Technology Commission "Explorer Project"
- National Natural Science Foundation of China
Cite
APA
Guo, X., Shi, Z., Wang, B., Cai, W., Wang, B., Wen, S., Zhang, X., Zhu, J., Yuan, J., Fan, X., Chen, Z., Wang, H., & Li, H. (2026). Slow‐Flow‐Sensitive Artery‐Vein‐Separated Velocity Mapping ( SAM ) Phase Contrast MR Angiography: Initial Evaluation of Hand Vasculature. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70375
Vancouver
Guo X, Shi Z, Wang B, Cai W, Wang B, Wen S, et al. Slow‐Flow‐Sensitive Artery‐Vein‐Separated Velocity Mapping ( SAM ) Phase Contrast MR Angiography: Initial Evaluation of Hand Vasculature. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70375
BibTeX
@article{Guo2026,
author = {Guo, Xin and Shi, Zhang and Wang, Bingyi and Cai, Weirui and Wang, Bei and Wen, Shaokang and Zhang, Xijing and Zhu, Jiayu and Yuan, Jianmin and Fan, Xianghua and Chen, Zhensen and Wang, He and Li, Hao},
title = {Slow‐Flow‐Sensitive Artery‐Vein‐Separated Velocity Mapping ( SAM ) Phase Contrast MR Angiography: Initial Evaluation of Hand Vasculature},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70375}
}
EUVIMED