Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2025. Verfasst von Changyu Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biomedical Engineering, University of Missouri, Columbia, Missouri, USA. Hauptthemen laut MEDLINE: Heart, Image Processing, Computer-Assisted, Image Interpretation, Computer-Assisted, Diffusion Magnetic Resonance Imaging. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: University of Missouri Research Council Fund.
Abstract (Originalsprache)
Purpose
The aim of the work is to develop a cascaded diffusion‐based super‐resolution model for low‐resolution (LR) MR tagging acquisitions, which is integrated with parallel imaging to achieve highly accelerated MR tagging while enhancing the tag grid quality of low‐resolution images.
Methods
We introduced TagGen, a diffusion‐based conditional generative model that uses low‐resolution MR tagging images as guidance to generate corresponding high‐resolution tagging images. The model was developed on 50 patients with long‐axis‐view, high‐resolution tagging acquisitions. During training, we retrospectively synthesized LR tagging images using an undersampling rate (R) of 3.3 with truncated outer phase‐encoding lines. During inference, we evaluated the performance of TagGen and compared it with REGAIN, a generative adversarial network–based super‐resolution model that was previously applied to MR tagging. In addition, we prospectively acquired data from 6 subjects with three heartbeats per slice using 10‐fold acceleration achieved by combining low‐resolution R = 3.3 with GRAPPA‐3 (generalized autocalibrating partially parallel acquisitions 3).
Results
For synthetic data ( R = 3.3), TagGen outperformed REGAIN in terms of normalized root mean square error, peak signal‐to‐noise ratio, and structural similarity index ( p < 0.05 for all). For prospectively 10‐fold accelerated data, TagGen provided better tag grid quality, signal‐to‐noise ratio, and overall image quality than REGAIN, as scored by two (blinded) radiologists ( p < 0.05 for all).
Conclusions
We developed a diffusion‐based generative super‐resolution model for MR tagging images and demonstrated its potential to integrate with parallel imaging to reconstruct highly accelerated cine MR tagging images acquired in three heartbeats with enhanced tag grid quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemical and Biomedical Engineering, University of Missouri, Columbia, Missouri, USA.
- Department of Radiology, University of Missouri, Columbia, Missouri, USA.
- Department of Medicine, University of Missouri, Columbia, Missouri, USA.
ORCID-Profile: Changyu Sun
Förderung
- University of Missouri Research Council Fund
Zitieren
APA
Sun, C., Thornburgh, C., Wang, Y., Kumar, S., & Altes, T. A. (2025). TagGen : Diffusion‐based generative model for cardiac MR tagging super resolution. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30422
Vancouver
Sun C, Thornburgh C, Wang Y, Kumar S, Altes TA. TagGen : Diffusion‐based generative model for cardiac MR tagging super resolution. Magnetic Resonance in Medicine. 2025. doi:10.1002/mrm.30422
BibTeX
@article{Sun2025,
author = {Sun, Changyu and Thornburgh, Cody and Wang, Yu and Kumar, Senthil and Altes, Talissa A},
title = {TagGen : Diffusion‐based generative model for cardiac MR tagging super resolution},
journal = {Magnetic Resonance in Medicine},
year = {2025},
doi = {10.1002/mrm.30422}
}
EUVIMED