EUVIMEDOpdag EUVIMED
FallberichtOpen access · CC BY 4.0

Quantitative Imaging of Pyruvate Metabolism in a Patient With Anaplastic Thyroid Cancer

James A Bankson iD, Joshua S Niedzielski, Collin J Harlan iD, Yunyun Chen, Christopher M Walker iD, Philip L Lorenzi, Lin Tan, Vikas Kundra, Matthew E Merritt, Mukundan Ragavan iD, Dawid Schellingerhout, Renjie He and 7 more

Magnetic Resonance in Medicine · 2026-08 · 96 (2) · 826-838

DOI: 10.1002/mrm.70351 ↗

At a glance

Fallbericht in Magnetic Resonance in Medicine, published online on 2026-03-24. Written by James A Bankson and 18 co-authors. Institution: Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA. Major MEDLINE topics: Pyruvic Acid, Magnetic Resonance Imaging, Thyroid Neoplasms. 39 references. The full text is freely available (open access, CC BY 4.0). Funded by: NCI NIH HHS, Cancer Prevention and Research Institute of Texas, GE Healthcare.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Magnetic resonance imaging using hyperpolarized (HP) [1‐ 13 C]‐pyruvate enables assessment of pyruvate metabolism in vivo and offers new insight into metabolic changes in response to cancer therapy. Widely used semi‐quantitative metrics of pyruvate metabolism can be affected by physiological factors that are extrinsic to intracellular metabolism. A validated pharmacokinetic (PK) model for analysis of intracellular pyruvate metabolism is needed to enhance the accuracy of quantitative metrics and clinical translation of metabolic MRI using HP pyruvate.

Methods

A PK model with two physical compartments and two chemical pools was developed to analyze the conversion of labeled pyruvate into lactate in vitro. Cells exposed to [U‐ 13 C 3 ]‐pyruvate were analyzed using pseudo‐dynamic ion‐coupled mass spectrometry (IC‐MS) while cells exposed to HP [1‐ 13 C]‐pyruvate were analyzed using dynamic NMR. The model was extended to incorporate a third physical compartment for vascular delivery, and quantification of changes in pyruvate metabolism in a patient with ATC was compared against semi‐quantitative metrics.

Results

Good correspondence between complementary quantitative measures of pyruvate metabolism using IC‐MS and NMR support the use of this framework as a foundation for quantitative analysis of HP pyruvate metabolism in vitro and in vivo. The three‐compartment model identified changes in vascular delivery separately from changes in intracellular pyruvate metabolism, revealed greater heterogeneity in metabolic activity, and identified areas of persistent high metabolic activity against an overall reduction in tumor metabolism after 8 days of treatment.

Conclusion

This framework for analysis provides a validated approach and demonstrates feasibility for quantitative evaluation of HP pyruvate metabolism in vivo.

Subjects

MeSH terms (MEDLINE)

Pyruvic AcidMagnetic Resonance ImagingThyroid NeoplasmsHumansMagnetic Resonance SpectroscopyCarbon Isotopes

Author keywords

cancer metabolismhyperpolarized pyruvatepharmacokinetic analysisquantitative imaging

Substances

Pyruvic AcidCarbon Isotopes

Authors and institutions

  • Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, Texas, USA.
  • Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Metabolomics Core Facility, Department of Bioinformatics and Computational Biology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
  • Department of Abdominal Imaging, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.

ORCID profiles: James A Bankson, Collin J Harlan, Christopher M Walker, Mukundan Ragavan

Funding

  • NCI NIH HHS
  • Cancer Prevention and Research Institute of Texas
  • GE Healthcare
  • National Cancer Institute

Cite

APA

Bankson, J. A., Niedzielski, J. S., Harlan, C. J., Chen, Y., Walker, C. M., Lorenzi, P. L., Tan, L., Kundra, V., Merritt, M. E., Ragavan, M., Schellingerhout, D., He, R., Ding, Y., Datar, S., Wang, Q., Peterson, C. B., Fuller, C. D., Sandulache, V. C., & Lai, S. Y. (2026). Quantitative Imaging of Pyruvate Metabolism in a Patient With Anaplastic Thyroid Cancer. Magnetic Resonance in Medicine, 96(2), 826-838. https://doi.org/10.1002/mrm.70351

Vancouver

Bankson JA, Niedzielski JS, Harlan CJ, Chen Y, Walker CM, Lorenzi PL, et al. Quantitative Imaging of Pyruvate Metabolism in a Patient With Anaplastic Thyroid Cancer. Magnetic Resonance in Medicine. 2026;96(2):826-838. doi:10.1002/mrm.70351

BibTeX
@article{Bankson2026,
  author = {Bankson, James A and Niedzielski, Joshua S and Harlan, Collin J and Chen, Yunyun and Walker, Christopher M and Lorenzi, Philip L and Tan, Lin and Kundra, Vikas and Merritt, Matthew E and Ragavan, Mukundan and Schellingerhout, Dawid and He, Renjie and Ding, Yao and Datar, Sahana and Wang, Qing and Peterson, Christine B and Fuller, Clifton D and Sandulache, Vlad C and Lai, Stephen Y},
  title = {Quantitative Imaging of Pyruvate Metabolism in a Patient With Anaplastic Thyroid Cancer},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {2},
  pages = {826--838},
  doi = {10.1002/mrm.70351}
}
Start for free →