Reducing Inhomogeneous MT ( ihMT ) Acquisition Time Using Frequency Alternation at Low Duty Cycle for Single Offset ( FALSO ) MT Preparations
Magnetic Resonance in Medicine · 2026-07 · 96 (1) · 191-202
DOI: 10.1002/mrm.70343 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 14.03.2026. Verfasst von Gopal Varma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of MRI Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Image Enhancement, Brain, Algorithms. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To evaluate Frequency Alternation at Low duty cycle for Single Offset (FALSO) as a novel Magnetization Transfer (MT) preparation scheme to increase speed and/or spatial resolution of inhomogeneous MT (ihMT) MRI by reducing the number of volumes required.
Methods
We compared FALSO MT to standard single frequency MT preparations using signal simulations and ihMT data acquired in a rat brain at 9.4 T and human brains at 3 T. Using FALSO MT preparations, combined with optimized Variable Flip Angle (VFA) MPRAGE readouts, we also acquired ihMT data at high resolution (down to 1.4 mm isotropic) to demonstrate the reduction in acquisitions required for ihMT images of sufficient SNR.
Results
We found no statistically significant difference between ihMT ratios from data acquired using FALSO MT preparations versus averaging data following separate positive and negative frequency offset MT acquisitions (as in regular ihMT to account for MT asymmetry). Use of VFA (relative to constant flip angle) readouts allowed high‐resolution ihMT images with a minimal number of volumes to be acquired and reduced variance in ihMT ratios within ROIs.
Conclusion
FALSO MT preparations allow for a reduction in the number of acquisitions required for ihMT while still controlling for MT asymmetry. IhMT data acquired with VFA readouts allow for higher resolution acquisitions in the same scan time. The combination of FALSO MT and VFA readouts can be used to increase the spatial and/or temporal resolution of ihMT experiments, allowing for easier clinical translation and improving the utility of ihMT in neurological studies of myelin.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of MRI Research, Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA.
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France.
ORCID-Profile: Gopal Varma, Aaron K Grant, Lucas Soustelle, Olivier M Girard, Guillaume Duhamel, David C Alsop
Zitieren
APA
Varma, G., Grant, A. K., Soustelle, L., Girard, O. M., Duhamel, G., & Alsop, D. C. (2026). Reducing Inhomogeneous MT ( ihMT ) Acquisition Time Using Frequency Alternation at Low Duty Cycle for Single Offset ( FALSO ) MT Preparations. Magnetic Resonance in Medicine, 96(1), 191-202. https://doi.org/10.1002/mrm.70343
Vancouver
Varma G, Grant AK, Soustelle L, Girard OM, Duhamel G, Alsop DC. Reducing Inhomogeneous MT ( ihMT ) Acquisition Time Using Frequency Alternation at Low Duty Cycle for Single Offset ( FALSO ) MT Preparations. Magnetic Resonance in Medicine. 2026;96(1):191-202. doi:10.1002/mrm.70343
BibTeX
@article{Varma2026,
author = {Varma, Gopal and Grant, Aaron K and Soustelle, Lucas and Girard, Olivier M and Duhamel, Guillaume and Alsop, David C},
title = {Reducing Inhomogeneous MT ( ihMT ) Acquisition Time Using Frequency Alternation at Low Duty Cycle for Single Offset ( FALSO ) MT Preparations},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {1},
pages = {191--202},
doi = {10.1002/mrm.70343}
}
EUVIMED