Spatial Image Gradient Estimation From the Diffusion MRI Profile
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70258 ↗At a glance
Journal article in Magnetic Resonance in Medicine, 2026. Written by Iman Aganj and 4 co-authors. Institution: Athinoula A. Martinos Center for Biomedical Imaging, Radiology Department, Massachusetts General Hospital, Harvard Medical School, Boston, Massachuse…. Major MEDLINE topics: Diffusion Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. 63 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: NIH Shared Instrumentation, Harvard Data Science Initiative, Harvard University, NIA NIH HHS.
Abstract (original language)
Purpose
In the course of diffusion, water molecules encounter varying values for the relaxation‐time properties of the underlying tissue. This factor, which has rarely been accounted for in diffusion MRI (dMRI), is modeled in this work, allowing for the estimation of the gradient of relaxation‐time properties from the dMRI signal.
Methods
With the aim of mining the dMRI data for information about spatial variations in tissue relaxation‐time properties, a new mathematical relationship between the diffusion signal and the spatial gradient of the image is derived, enabling the estimation of the latter from the former. The hypothesis was validated on human brain dMRI images from three datasets: the public Human Connectome Project Young Adults database, 10 healthy volunteers and 1 ex vivo sample scanned in‐house with stimulated‐echo diffusion encoding and a long diffusion time of 1 s (which we have made publicly available), and three subjects from the public Multi‐TE database. The effects of the confounding factor of “fiber continuity” were furthermore measured.
Results
The spatial image gradient estimated from the diffusion signal was compared to the gold‐standard spatial gradient approximated using the finite difference method. The former gradient was significantly related to the latter in all datasets (i.e., with a difference significantly smaller than chance), with an effect distinct from fiber continuity.
Conclusion
The results support the hypothesized relationship between within‐voxel dMRI signal and image gradient, with an effect that was not explainable by the confounding factor of fiber continuity.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Athinoula A. Martinos Center for Biomedical Imaging, Radiology Department, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
- Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.
ORCID profiles: Iman Aganj
Funding
- NIH Shared Instrumentation
- Harvard Data Science Initiative, Harvard University
- NIA NIH HHS
- National Institute for Neurological Disorders and Stroke
- Massachusetts Life Sciences Center
- National Institute for Biomedical Imaging and Bioengineering
- Michael J. Fox Foundation for Parkinson's Research
- NIMH NIH HHS
Cite
APA
Aganj, I., Feiweier, T., Kirsch, J. E., Fischl, B. R., & van der Kouwe, A. J. (2026). Spatial Image Gradient Estimation From the Diffusion MRI Profile. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70258
Vancouver
Aganj I, Feiweier T, Kirsch JE, Fischl BR, van der Kouwe AJ. Spatial Image Gradient Estimation From the Diffusion MRI Profile. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70258
BibTeX
@article{Aganj2026,
author = {Aganj, Iman and Feiweier, Thorsten and Kirsch, John E and Fischl, Bruce R and van der Kouwe, Andre J},
title = {Spatial Image Gradient Estimation From the Diffusion MRI Profile},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70258}
}
EUVIMED