Real‐Time Phase‐Contrast Cardiovascular MRI Using a Deep Learning Reconstruction Network With Combined Dictionary Learning and CNN
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70142 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Sifan Wu und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shangha…. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Shanghai Science and Technology Commission Explorer Program, National Key Research and Development Program of China.
Abstract (Originalsprache)
Purpose
This study aims to develop real‐time phase‐contrast (PC) cardiovascular MRI with low latency.
Methods
In this study, a framework using golden‐angle radial sequence and a deep‐learning‐based reconstruction network, named DLCNet, is proposed for real‐time PC cardiovascular MRI. The DLCNet is designed to capture both spatial and temporal features by combining dictionary learning and CNN. A dataset of 15 normal subjects was acquired and utilized to train and test the DLCNet. The reconstructed image quality and flow measurements at the ascending aorta were compared with different reconstruction algorithms. Real‐time PC cardiovascular MRI was demonstrated with low latency using the proposed framework via Gadgetron platform at a scanner. The prospectively reconstructed results were compared with those obtained from electrocardiograph (ECG)‐gated, breath‐hold, segmented PC.
Results
The proposed reconstruction network outperformed other algorithms in both image reconstruction quality and flow quantification. The overall framework achieved an imaging speed of 14.6 frames per second, with an image display latency of less than 60 ms. The real‐time flow quantification results showed good agreement with ECG‐gated, breath‐hold, segmented PC‐MRI.
Conclusion
The proposed framework was successfully demonstrated for real‐time PC cardiovascular MRI with high‐quality image reconstruction and low‐latency image display.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Shanghai United Imaging Healthcare Co., Ltd, Shanghai, China.
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China.
ORCID-Profile: Sifan Wu, Zhijun Wang
Förderung
- Shanghai Science and Technology Commission Explorer Program
- National Key Research and Development Program of China
Zitieren
APA
Wu, S., She, H., Wang, Z., Tong, L., Wang, Z., & Du, Y. P. (2026). Real‐Time Phase‐Contrast Cardiovascular MRI Using a Deep Learning Reconstruction Network With Combined Dictionary Learning and CNN. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70142
Vancouver
Wu S, She H, Wang Z, Tong L, Wang Z, Du YP. Real‐Time Phase‐Contrast Cardiovascular MRI Using a Deep Learning Reconstruction Network With Combined Dictionary Learning and CNN. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70142
BibTeX
@article{Wu2026,
author = {Wu, Sifan and She, Huajun and Wang, Zhijun and Tong, Li and Wang, Zhenkui and Du, Yiping P},
title = {Real‐Time Phase‐Contrast Cardiovascular MRI Using a Deep Learning Reconstruction Network With Combined Dictionary Learning and CNN},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70142}
}
EUVIMED