EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

DREAMER : Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue

Brian-Tinh Duc Vu iD, Nada Kamona iD, Felix W Wehrli iD, Rajiv S Deshpande iD, Hee Kwon Song, Allison Hu, Emily Baccaglini, Scott P Bartlett, Chamith S Rajapakse

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70140 ↗

At a glance

Journal article in Magnetic Resonance in Medicine, 2026. Written by Brian-Tinh Duc Vu and 8 co-authors. Institution: Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Major MEDLINE topics: Magnetic Resonance Imaging, Skull, Image Processing, Computer-Assisted, Image Interpretation, Computer-Assisted. 75 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIAMS NIH HHS, NIH HHS, Children's Hospital of Philadelphia.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

Pediatric craniofacial imaging may involve examination of both the skull and brain tissues via CT and MRI, respectively. DREAMER (Dual Repetition and Echo Acquisition with Multi‐contrast Encoding and Reconstruction) simultaneously acquires solid‐ and soft‐tissue images, potentially providing a rapid, high‐resolution, and radiation‐free protocol whenever bone‐selective, T 1 w, and T 2 w images are required.

Methods

The DREAMER sequence combines a solid‐state MRI method with phase‐based T 2 encoding to produce a multi‐contrast signal model that enables retrospective customization of image contrast weighting. DREAMER is paired with an iterative image reconstruction algorithm for accelerated and high‐resolution structural imaging of solid‐ and soft‐tissue compartments. Two healthy adult volunteers and two pediatric patients were scanned at 3 T to qualitatively compare soft‐tissue DREAMER image contrasts with their corresponding clinical standards, T 1 w MPRAGE and T 2 w fast spin‐echo (FSE). Two patients also underwent clinical CT to compare the bone‐selective images and skull renderings.

Results

DREAMER images are self‐registered, high‐resolution, and spatially isotropic. The bone‐selective, T 1 w, and T 2 w images approximate the image contrasts and structural imaging capabilities of their corresponding clinical standards (CT, T 1 w MPRAGE, and T 2 w FSE). Unlike the standard techniques, DREAMER imaging occurs at a single scanner using a single pulse sequence.

Conclusion

DREAMER combines mechanisms for solid‐ and multiple‐contrast soft‐tissue imaging into a single scan. For craniofacial imaging, DREAMER may consolidate CT and MRI demand, reduce exposure to ionizing radiation, decrease patient examination and wait times, and simplify the radiological workflow.

Subjects

MeSH terms (MEDLINE)

Magnetic Resonance ImagingSkullImage Processing, Computer-AssistedImage Interpretation, Computer-AssistedHumansAdultAlgorithmsMaleChildFemaleBrainImage EnhancementReproducibility of Results

Author keywords

craniofacial imagingmulti‐contrast MRIpediatric imagingpulse sequencesolid‐state imaging

Authors and institutions

  • Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Department of Bioengineering, School of Engineering and Applied Sciences, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Division of Plastic, Reconstructive and Oral Surgery, Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA.
  • Department of Orthopaedic Surgery, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.

ORCID profiles: Brian-Tinh Duc Vu, Nada Kamona, Felix W Wehrli, Rajiv S Deshpande

Funding

  • NIAMS NIH HHS
  • NIH HHS
  • Children's Hospital of Philadelphia
  • National Science Foundation
  • NIBIB NIH HHS
  • NIDCR NIH HHS
  • Hospital of the University of Pennsylvania
  • National Institutes of Health

Cite

APA

Vu, B. D., Kamona, N., Wehrli, F. W., Deshpande, R. S., Song, H. K., Hu, A., Baccaglini, E., Bartlett, S. P., & Rajapakse, C. S. (2026). DREAMER : Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70140

Vancouver

Vu BD, Kamona N, Wehrli FW, Deshpande RS, Song HK, Hu A, et al. DREAMER : Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70140

BibTeX
@article{Vu2026,
  author = {Vu, Brian-Tinh Duc and Kamona, Nada and Wehrli, Felix W and Deshpande, Rajiv S and Song, Hee Kwon and Hu, Allison and Baccaglini, Emily and Bartlett, Scott P and Rajapakse, Chamith S},
  title = {DREAMER : Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70140}
}
Start for free →