Repeatability of diffusion‐weighted arterial spin labeling MRI for mapping blood–brain barrier water exchange rate at different postlabel delays
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70081 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Yufei D Zhu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of California, Davis, Davis, California, USA. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Blood-Brain Barrier. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NIH HHS, NCATS NIH HHS.
Abstract (Originalsprache)
Purpose
This study sought to determine the intrasession repeatability of the diffusion‐weighted (DW) arterial spin labeling (ASL) sequence at different postlabel delays (PLDs).
Methods
We first performed numerical simulations to study the accuracy of the two‐compartment water exchange rate (Kw) fitting model with added Gaussian noise for DW PLDs at 1500, 1800, and 2100 ms. Ten young, healthy participants then underwent a structural T 1 scan and two intrasession in vivo DW ASL scans at each PLD on a 3T MRI. The Kw, arterial transit time (ATT), and cerebral blood flow maps were linearly registered to the structural images, which were then segmented using FreeSurfer into masks with 35 bilateral gray‐matter regions.
Results
Simulation results showed that the Kw fitting model performed at an error rate less than 10% at physiological ATTs and Kw values, but that error and bias increased at a PLD of 2100 ms and at ATT ranges where the overall blood signal fraction (A 1 ) is low. In vivo analysis showed a significant positive correlation between intrasession measurements of regional Kw at a DW PLD of 1800 ms ( β = 0.33, p < 0.001) only. Furthermore, a significant positive relationship between Kw and cerebral blood flow was seen at a DW PLD of 1500 ms ( β = 0.26, p = 0.005) and DW PLD of 2100 ms ( β = 0.39, p = 0.006).
Conclusion
Overall, DW ASL provides the strongest intrasession repeatability at a PLD of 1800 ms in young, healthy subjects, and a simulation study shows accurate Kw fits at physiologic range of ATTs and Kw values.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of California, Davis, Davis, California, USA.
- Department of Neurology, University of California, Davis, Davis, California, USA.
- Stevens Neuroimaging and Informatics Institute, University of Southern California, Los Angeles, California, USA.
- Department of Radiology, University of California, Davis, Davis, California, USA.
- Department of Radiology and Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
ORCID-Profile: Yufei D Zhu
Förderung
- NINDS NIH HHS
- NIH HHS
- NCATS NIH HHS
- National Institutes of Health
Zitieren
APA
Zhu, Y. D., Lee, Q. N., Shao, X., Jung, Y., Wang, D. J. J., & Fan, A. P. (2026). Repeatability of diffusion‐weighted arterial spin labeling MRI for mapping blood–brain barrier water exchange rate at different postlabel delays. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70081
Vancouver
Zhu YD, Lee QN, Shao X, Jung Y, Wang DJJ, Fan AP. Repeatability of diffusion‐weighted arterial spin labeling MRI for mapping blood–brain barrier water exchange rate at different postlabel delays. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70081
BibTeX
@article{Zhu2026,
author = {Zhu, Yufei D and Lee, Quimby N and Shao, Xingfeng and Jung, Youngkyoo and Wang, Danny J J and Fan, Audrey P},
title = {Repeatability of diffusion‐weighted arterial spin labeling MRI for mapping blood–brain barrier water exchange rate at different postlabel delays},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70081}
}
EUVIMED