EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On the structural and practical identifiability of multi‐echo BBB‐ASL tracer kinetic models

Tabitha J Manson iD, David L Thomas iD, Matthias Günther iD, Lynette J Tippett, Michael Dragunow, Catherine A Morgan, Vinod Suresh

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70075 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Tabitha J Manson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand. Hauptthemen laut MEDLINE: Blood-Brain Barrier, Magnetic Resonance Imaging. Die Arbeit nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Neurological Foundation of New Zealand, New Zealand Dementia Prevention Trust, Sir Thomas and Lady Duncan Trust.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Tracer kinetic models are used in arterial spin labeling (ASL); however, deciding which model parameters to fix or fit is not always trivial. The identifiability of the resultant system of equations is useful to consider, since it will likely impact parameter uncertainty. Here, we analyze the identifiability of two‐compartment models used in multi‐echo (ME) blood–brain‐barrier (BBB)‐ASL and evaluate the reliability of the fitted water‐transfer rate ).

Method

The identifiability of two variants of a two‐compartment model (referred to here as “series” and “parallel”) were analyzed using sensitivity matrix and Monte‐Carlo simulation methods, the latter including the effects of noise and fixed‐parameter error. ME‐ASL data were collected at 3T in 25 cognitively normal participants (57–85 y). In one volunteer, additional scans were acquired to estimate noise. Fits for whole‐gray‐matter were performed with a theoretically identifiable version of the model.

Results

All models needed one or more fixed parameters to be structurally identifiable, with different combinations required for each. Practical identifiability analysis yielded estimates with a median absolute error of 29% (parallel model) and 33% (series model). Fits to data yielded median values of 0 (parallel) and 96 min −1 (series).

Conclusion

We used identifiability analysis to determine an appropriate BBB‐ASL model for acquired data. Through simulations we showed that parameter estimates depend on model selection and the value of fixed parameters. We demonstrated that fixed‐parameter value and errors significantly impact the reliability of values obtained from acquired ME‐ASL images, even with structurally identifiable models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood-Brain BarrierMagnetic Resonance ImagingHumansMiddle AgedAgedFemaleMaleReproducibility of ResultsMonte Carlo MethodSpin LabelsAged, 80 and overKineticsComputer SimulationBrainAlgorithmsImage Processing, Computer-Assisted

Stichwörter der Autor:innen

arterial spin labelingblood–brain barriercerebral blood flowidentifiabilitywater exchangewater permeability

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.
  • School of Psychology and Centre for Brain Research, University of Auckland, Auckland, New Zealand.
  • Department of Brain Repair and Rehabilitation, UCL Queen Square Institute of Neurology, University College London, London, UK.
  • Imaging Physics, Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany.
  • MR imaging and spectroscopy, Faculty 1 (Physics/Electrical Engineering), University Bremen, Bremen, Germany.
  • Dementia Prevention Research Clinic, University of Auckland, Auckland, New Zealand.

ORCID-Profile: Tabitha J Manson, David L Thomas, Matthias Günther

Förderung

  • Neurological Foundation of New Zealand
  • New Zealand Dementia Prevention Trust
  • Sir Thomas and Lady Duncan Trust
  • Health Research Council of New Zealand
  • Freemasons New Zealand
  • Brain Research New Zealand

Zitieren

APA

Manson, T. J., Thomas, D. L., Günther, M., Tippett, L. J., Dragunow, M., Morgan, C. A., & Suresh, V. (2026). On the structural and practical identifiability of multi‐echo BBB‐ASL tracer kinetic models. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70075

Vancouver

Manson TJ, Thomas DL, Günther M, Tippett LJ, Dragunow M, Morgan CA, et al. On the structural and practical identifiability of multi‐echo BBB‐ASL tracer kinetic models. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70075

BibTeX
@article{Manson2026,
  author = {Manson, Tabitha J and Thomas, David L and Günther, Matthias and Tippett, Lynette J and Dragunow, Michael and Morgan, Catherine A and Suresh, Vinod},
  title = {On the structural and practical identifiability of multi‐echo BBB‐ASL tracer kinetic models},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70075}
}
Kostenlos starten →